Hitachi PC-ARFH1E1 02 Manual De Instrucciones página 46

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 69
PC-ARFH1E1(02/03) FUNCTIONALITIES
Space priority temperature:
Threshold value of outdoor ambient
temperature for the activation of the
space priority function.
• Range: -20~0 ºC
• Only available in Standard mode.
DHW Heater: Only available when DHW
heater is activated (DSW4 pin 3 ON).
• Waiting time: Enable or disable
waiting time for DHW heater.
• Electrical Heater waiting time:
Waiting time for the beginning of
electrical heater operation since
compressor start-up.
• Only available in High Speed control.

Anti Legionella function
1.8.2.6 Swimming Pool configuration
38
PMML0626 rev.0 - 07/2022
3 / 3
Status of anti legionella operation (enabled/d)
Specified day for anti legionella operation
Specified time of the day for anti legionella operation
Setting for domestic hot water temperature in anti legionella operation..
Duration of shock treatment. Between 10 to 60 minutes.
Status:
Enable or disable swimming pool.
Set input 3, output 1 and sensor 2. (see section
and Sensors
configuration")
Setting temperature:
Adjustment of the swimming pool water
temperature setting.
• Range: 24~33 ºC
Offset temperature: The setting temperature is
increased by the indicated parameter.
Anti Legionella:
In order to help prevent against Legionella in
the DHW system, the DHW set point can be
raised to a higher than normal temperature.
The Legionella protection only makes sense if
there is a DHW electric heater to raise the DHW
temperature to this high temperature.
See the possible configurable parameters
below.
Smart Configuration: Option to allow the tank
to be heated to an intermediate temperature of
comfort in conditions of water consumption in
order to avoid heating to the traditional setting
temperature (Only available in Economic mode).
• Comfort setting: Intermediate target
temperature of tank heating under water
consumption conditions
• Comfort cycles: Number of operations
allowed to heat water to the comfort
temperature.
"1.8.2.10 Inputs, Outputs
loading

Este manual también es adecuado para:

Pc-arfh1e1 03