PC-ARFH1E1(02/03) FUNCTIONALITIES
1.6.2 Advanced Configuration
Select the advance configuration for a complete configuration.
•
•
Press OK button.
•
Select the controller type:
-
Unit: the device controls the unit.
Room: the device acts as a room thermostat of a zone.
-
-
Unit + Room: the device controls the unit and acts as a room thermostat.
•
Select controlled circuits by this device: Room C1, Room C2, Room C1+C2
•
Select the favourite action: Eco/Confort, Timer, Night shift.
•
Select Enabled or Disabled for European summer time.
•
Select Next and press OK button .
Configure circuit 1 and circuit 2 OTC: Disabled, Points, Gradient, Fix.
•
•
Enable or disable DHW and Swimming Pool.
•
Select the heating source: HP only, HP + EH, HP + Boiler.
Configure electrical heater use: Starting or Backup.
•
Configure Boiler type: Parallel or Serial.
•
Configure Solar Combination options: Disabled, Input Demand, Total Control. (only in case DHW is enabled).
•
•
Enable or disable Hydraulic separator status.
•
Select Next and press OK button.
18
PMML0626 rev.0 - 07/2022