DESCRIPTION OF THE PRODUCT
1
ELEMENTS OF THE COMPLETE INSTALLATION
INSTALLATION COMPONENTS:
1
Operator (VULCAN)
2
Flashing light (TOP9 only)
3
Gate
4
Exterior photocells
5
Key selector
6
Wall button
7
Control panel
8
Connections box
9
Underground electrical installation
10 Interior photocells (TOP9 only)
11 Electrolock
12 External closing stopper
13 Reception antenna
ELECTRICAL CABLING:
Element
A: General power supply
B: Flashing light
C: Photocells
D: Key selector
E: Operator / Ends of travel
F: Antenna
Fig. 1
Elements of the complete installation (swing gate)
The safe and correct operation of the installa-
tion is the responsibility of the installer.
The closing stopper (12) is an essential element.
If the photocells (4) and (10) or the VUS operator are not
installed, the Dead Man mode must be programmed in
the control panel in order to comply with legislation
(DIP10 ON and DIP 4 OFF).
Nº threads x section
2
3x1.5mm
2
2x0.5mm
2
2x0.5mm
2
2x0.5mm
2
2
4x0.75mm
/ 4x0.5mm
Shielded cable
The facility is operated by way of the button (6) or
wall key (5), or using the remote control.
Maximum length
30m
20m
30m
25m
20m
5m
Control panel AEP10-009/ AEP10TOP9