MAINTENANCE
- subsequently, remove the side bricks (3), the rear bricks (4) and the
fire bed (5).
3
4
5
To mount the fire bricks, perform the above procedure in reverse or-
der.
11.3 REMOVING THE FUME ADAPTER
To remove the fume adapter, proceed as follows:
- open the door of the appliance, consult the paragraph
door"
- remove the upper fire bricks, consult the paragraph
fire
bricks"
- loosen the fixing screws and remove the fume adapter from the
inside; disconnect any pipes present.
CS.VES.IST-1_EN_Rev. 0.0_09-23
3
Fig. 34
"Opening the
"Removing the
Su
Fig. 35
Perform the above procedure in reverse order to mount the fume
adapter.
a
The fume connector is fitted with a seal that could
get damaged when dismantling the component. Be-
fore putting the fume connector back on, verify that
the seal is intact; if not, it must be replaced.
11.4 EXTRACTING THE COMBUSTION CHAMBER
To extract the combustion chamber, proceed as follows:
- open the door of the appliance, consult the paragraph
door"
- remove the upper fire bricks, consult the paragraph
fire
bricks"
- remove the fume connector, consult the paragraph
fume
adapter"
- loosen the fixing screws (1) and extract the combustion chamber
(2).
2
To mount the combustion chamber, perform the above procedure in
reverse order.
EN
"Opening the
"Removing the
"Removing the
x2
1
Fig. 36