Idiomas disponibles

Changing the parameter setting on the tool (Field Setting mode)
NOTICE:
This function is available by default. If you have disabled the Field Setting mode on the computer,
enable this function beforehand. Refer to the instruction manual of "Makita Industry Tool Settings" for how to
configure.
NOTICE:
If the Field Setting mode is disabled, making settings on the tool is not available. When you press the
setting button, the values set on the tool are displayed in order.
The current setting number is displayed on the indicator.
Every time you press the setting button, the indicator shows torque level, rundown level, workable time range, and
"Ad".
1
► 1. Setting button 2. Indicator
You can change the following parameter settings on your tool:
Auto-stop setting / Free mode
Setting item
Torque level
Rundown level
Workable time range
NOTICE:
If "OP" (Loosening Auto Stop mode) is displayed on the indicator, torque level setting and rundown
level setting is not available. In this case, change the mode to Tightening Auto Stop mode, and then set the torque
level and rundown level on the computer using "Makita Industry Tool Settings".
Changing the torque level
When changing the torque level from 23 to 34
1.
Press the setting button several times until the
indicator shows 2-digit number which stands for
the current setting of the torque level.
2
Display on the indicator
01 - 40
FF
OP
L1 - L7
OP
Lo: 0.1 - 9.9
HI: 0.1 - 9.9
-.-
The torque level at which the Tightening
Auto Stop mode works
The sensitivity of the fastener seating
The shortest/longest duration of the rota-
tion when you continue to pull the switch
trigger.
2.
Press and hold the setting button until the number
in the tens place starts blinking.
3.
Set the number in the tens place by pressing the
setting button briefly. Every time you press the
setting button, the indicator shows the number
from "0" to "4" and "F" in a cycle.
4.
Press and hold the setting button until the number
in the ones place starts blinking.
5.
Set the number in the ones place by pressing the
setting button briefly. Every time you press the
setting button, the indicator shows the number
from "0" to "9" and "F" in a cycle.
6.
Press and hold the setting button for a few
seconds.
NOTE: If you are not sure which torque level is suit-
able for your work, set "FF" so that the tool operates
in the Free mode.
NOTE: If you input "00", "FF" is displayed instead of
"00".