Checking the welding
Optional operation isoweld
Fig. 2
Please note that the underside of the inductor must be positioned parallel to
the top face of the plate!
Technical data
Induction generator:
Workable temperature range: -5 °C to +50 °C
Electrical connection:
Power consumption:
Frequency:
Tool dimensions isoweld
Size:
550x520x1100 mm
Weight: 18.5 Kg (complete)
50
If the correct parameters have been selected for the welding
and the recommended test weld has been successful with
positive results, and the instructions in the operating instructions
have been followed, no further checks of the operation are
necessary.
If you are not sure whether certain joints have already been
welded, SFS recommends using the suction pad provided or a
commercially available suction device to carry out a test. Try to lift
the roofing membrane at the point in question. If that is possible,
the joint is still open and requires welding.
3000: working with the hand inductor
®
Alternatively it is also possible to carry out welds with the hand
inductor (available as an option). This may be appropriate on roof
upstands, around rooflights, on shed roofs etc.
The hand inductor is controlled via the main tool and automatically
adopts all functions and settings from it!
1. Unplug the inductor from the main tool
2. Plug the hand inductor into the main tool (see Fig. 2).
3. Carry out calibration as described in the "Calibration" section.
4. For further steps, see "Operation: welding" section.
110V / 230 V
1500 Watt
50 Hz / 60 Hz
3000:
®
(assembled)
Dimensions of transport box:
L/W/H: 770 x 560 x 500 mm
Weight: 19.5 Kg
Tool dimensions isoweld
Size:
590x340x390 mm
Weight: 18.5 Kg (complete)
3000m:
®
(assembled)