Safety instructions
General safety instructions – Part 2
• Always switch the tool off and remove the mains connector during breaks or
maintenance work. Do not leave the tool unattended.
• When carrying out maintenance and service work, the power connection to the tool
must be disconnected.
• Regularly check the tool for damage, and that it is functioning properly. Use the tool
only if it is functioning properly.
• Repairs may only be carried out by a specialist.
• Only use system components from SFS or approved by SFS. Do not use any
accessories or spare parts from other manufacturers without approval by
SFS.
• The functionality of this system is guaranteed when original fastener, stress plate,
sleeve and spare parts from SFS are used, and the unit is operated in accordance
with the operating instructions.
• isoweld
stress plates must be stored dry, covered and protected from
®
sunlight to prevent soiling and demage caused by UV radiation. isoweld
stress plates must not be exposed to the elements for more than 24 hours.
• During installation on EPS/XPS thermal insulation or on a fibre material, an
FI-Pad must always be used.
Special safety instructions
• When working on roofs with a slope of between 0 and 10° a guard rail must be
fixed at the edge of the roof.
• When the roof slope is more than 10° special safety devices must be employed.
• When the working height is more than 3 m above ground, appropriate fall prevention
measures must be employed (see below).
• Fall prevention measures for work lasting less than 2 working days. In the case of
work that takes longer, proceed as described above (see below).
>5 m
>3 m
®
35
>5 m