f) The high voltage symbol "
of ">30V" and the buzzer warns frequently if the voltage (AC/DC) is
more than 30V.
5. AC/DC VOLTAGE MEASUREMENTS
a). Set the range switch to ACV or DCV position.
b). Connect red test lead to "V Ω" terminal and black test lead to
terminal "COM".
c). Connect test prods of test leads IN PARALLEL to the circuit being
measured.
d). Read the voltage value on LCD.
6. BATTERY SAVER (SLEEP MODE)
The meter will automatically enter the "sleep mode" if there is no
function change or button press for 10 minutes, but it works as soon as
the rotary function switch is changed or a button is pressed.
7. POWER TOOLS AND SMALL APPLIANCES
This test would also apply to other similar equipment that has a line
cord. For double insulated power tools, the test lead shown connected
to the housing would be connected to some metal part of the tool(e.g.
chuck, blade).
Note: The switch of the device must be in the "ON" position
and the main power should be disconnected.
MOTORS
AC motors - Disconnect the motor from the line by disconnecting the
wires at the motor terminals or by opening the main switch. If the main
switch is used and the motor also has a starter then the starter must be
held, by some means, in the "ON" position. In the latter case, the
measured resistance will include the resistance of the motor, wire and
all other components between the motor and the main switch. If a
" flashes along with a primary display
9