en
ENGLISH
9.1
Cleaning the reversible blades
Paint might build up under the cutting edges of the
reversible blades. In this case, clean the edges of
the reversible blades using the graver (8).
9.2
Turn/replace the reversible blades
Use original Metabo reversible blades only.
Order no.: 631720000 (4 pieces)
Order no.: 631660000 (10 pieces)
Blunt edges of the reversible blades increase
the danger that the paint remover jams during
the milling operation and kicks back. Therefore turn/
replace blunt reversible blades in good time!
If required, clean Torx of the reversible blades using
a graver (8).
Axial reversible cutting plates:
Locking the cutter head.
Put the paint remover down and release locking
button.
Remove hexagonal wrench (9-a) and refit (9-b,
Torx).
Press the locking button (2) up to the stop and keep
pressed.
Radial reversible cutting plates:
Open protective flap. Turn cutter head with multi-
socket spanner until the reversible cutting blade is
accessible.
Remove the screws of the reversible blades (11)
with the Torx key(9-b). Loosen the reversible blade
(11) with the gravel and clean the support surface of
the reversible blades.
Insert the reversible blades (11) in such a way that
the sharp edges are pointing in the direction of
rotation.
If all edges are blunt, replace the reversible blade.
12
Always turn/replace both reversible blades!
Replace screws if the torx is damaged!
Tighten reversed/new reversible blades with 5 Nm.
Do not leave the Torx key in place!
9.3
Cleaning the cutter head and sliding
surface of the planing base
If required, clean the cutter head with agents
suitable for cleaning aluminium (pH value between
4.5 and 8).
9.4
Cleaning the extraction nozzle
During the milling operation, chips can get stuck in
the extraction nozzle (6) and clog the same.
Lodged chips can be loosened and removed
through the cleaning slit in the extraction nozzle
using the graver (8).
If required, remove the extraction nozzle (6).
Remove the Phillips screws and pull out the
extraction nozzle towards the rear. Clean extraction
nozzle (6) and planing base (10).
10. Accessories
Use only genuine Metabo accessories.
Use only accessories which fulfil the requirements
and specifications listed in these operating
instructions.
For a complete range of accessories, see
www.metabo.com or the catalogue.
11. Repairs
Repairs to electrical tools must be carried out by
qualified electricians ONLY!
A defective mains cable must only be replaced with
a special, original mains cable from metabo, which
is available only from the Metabo service.
If you have Metabo electrical tools that require
repairs, please contact your Metabo service centre.
For addresses see www.metabo.com.
You can download spare parts lists from
www.metabo.com.
12. Environmental Protection
Observe national regulations on environmentally
compatible disposal and on the recycling of disused
machines, packaging and accessories.
Packaging materials must be disposed of according
to their labelling in accordance with municipal
guidelines. Further information can be found at
www.metabo.com in the "Service" section.
Dispose of generated chips properly.
Only for EU countries: Never dispose of
power tools in your household waste! In
accordance with European Directive 2012/
19/EU on waste electrical and electronic equipment