The set pressure can be drawn from the
quick-lock coupling (5).
6.4 Setting the pressure switch
The pressure switch is set at the factory.
Cut-in pressure approx. 6 bar
Cut-out pressure approx. 8 bar
7. Replacing the power cable
Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
8. Cleaning, maintenance and
ordering of spare parts
Danger!
Pull the power plug before doing any
cleaning and maintenance work on the ap-
pliance.
Warning!
Wait until the compressor has completely
cooled down. Risk of burns!
Warning!
Always depressurize the tank before carrying
out any cleaning and maintenance work.
Danger!
After use, always switch off the equipment
immediately and pull out the power plug.
8.1 Cleaning
Keep the safety devices free of dirt and dust
as far as possible. Wipe the equipment with a
clean cloth or blow it with compressed air at
low pressure.
We recommend that you clean the appliance
immediately after you use it.
Clean the appliance regularly with a damp
cloth and some soft soap. Do not use
cleaning agents or solvents; these may be
aggressive to the plastic parts in the appli-
ance. Ensure that no water can get into the
interior of the appliance.
You must disconnect the hose and any
spraying tools from the compressor before
cleaning. Do not clean the compressor with
Anl_TC_AC_190_6_8_OF_SPK13.indb 15
Anl_TC_AC_190_6_8_OF_SPK13.indb 15
GB
water, solvents or the like.
8.2 Condensed water (Fig. 1)
Important! To ensure a long service life of the
pressure vessel (2), drain off the condensed
water by opening the drain screw (11) each time
after using.
Check the pressure vessel for signs of rust and
damage each time before using. Do not use the
compressor with a damaged or rusty pressure
vessel. If you discover any damage, please con-
tact the customer service workshop.
8.3 Safety valve (10)
The safety valve has been set for the highest per-
mitted pressure of the pressure vessel. It is prohi-
bited to adjust the safety valve or remove its seal.
Actuate the safety valve from time to time to en-
sure that it works when required. To do so, open
the screw cap of the valve while the tank is under
pressure. Once the screw cap has been fully ope-
ned you must pull it to let air escape through the
valve. Then screw the cap fully back in place.
8.4 Storage
Warning!
Pull the mains plug out of the socket and ventilate
the appliance and all connected pneumatic tools.
Switch off the compressor and make sure that it is
secured in such a way that it cannot be started up
again by any unauthorized person.
Warning!
Store the compressor only in a dry location
which is not accessible to unauthorized per-
sons. Always store upright, never tilted!
8.5 Transport
Transport the equipment only by carrying it by
the transport handle.
Protect the equipment against unexpected
knocks and vibrations.
8.6 Ordering replacement parts:
Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required