3. Proper use
The compressor is designed for generating
compressed air for tools operated by compressed
air.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Technical data
Mains connection: .................. 220-240 V ~ 50 Hz
Motor rating kW: ............................................ 1.2
Compressor speed min
Operating pressure bar: ................................... 8
Pressure vessel capacity (in liters): .................. 6
Theoretical suction rate l/min.: ..................... 190
Output (compressed air) at 7 bar: .... 55 liters/min
Output (compressed air) at 4 bar: .... 77 liters/min
Sound power level
LWA
Uncertainty K
....................................... 0.65 dB
WA
Sound pressure level L
Uncertainty K
........................................ 0.65 dB
pA
Protection type: ........................................... IP20
Weight of the unit in kg: ......................approx. 8.8
Danger!
Noise
The noise emission values were measured in ac-
cordance with EN ISO 3744.
5. Before starting the equipment
Warning!
Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
Examine the machine for signs of transit da-
mage. Report any damage immediately to the
company which delivered the compressor.
Anl_TC_AC_190_6_8_OF_SPK13.indb 14
Anl_TC_AC_190_6_8_OF_SPK13.indb 14
: ........................... 3800
-1
in dB: ........................... 97
in dB: ...................... 77
pA
GB
The compressor should be set up near the
working consumer.
Avoid long air lines and long supply lines (ex-
tensions).
Make sure the intake air is dry and dust-free.
Do not set up the compressor in damp or wet
rooms.
The compressor may only be used in suitable
rooms (with good ventilation and an ambient
temperature from +5°C to +40°C). There must
be no dust, acids, vapors, explosive gases or
inflammable gases in the room.
The compressor is designed to be used in dry
rooms. It is prohibited to use the compressor
in areas where work is conducted with spray-
ed water.
The equipment must be set up where it can
stand securely.
Use flexible hoses in order to prevent trans-
mitting unacceptable loads to the pipeline
system at the connection between the com-
pressor system and the pipeline system.
It is essential to use separators, traps and
drains which process the liquids produced by
the compressor before the compressor sys-
tem is put into operation.
Supply hoses at pressures above 7 bar
should be equipped with a safety cable (e.g.
a wire rope).
6. Assembly and starting
Important!
You must fully assemble the equipment befo-
re using it for the fi rst time.
6.1 Mains connection
Long supply cables, extensions, cable reels
etc. cause a drop in voltage and can impede
motor start-up.
At low temperatures below +5°C, sluggish-
ness may make starting difficult or impossib-
le.
6.2 ON/OFF switch (Fig. 1)
To switch on the equipment, set the On/Off switch
(8) to position 1.
To switch off the equipment, move the On/Off
switch (8) to position 0 .
6.3 Setting the pressure (Fig. 1)
You can adjust the pressure on the pressure
gauge (6) using the pressure regulator (7).