Pump runs continuously:
Float switch does not reach lower
position.
Make sure the float switch can
move unrestricted.
9. Repairs
A
Danger!
Repairs to electric tools must
only be carried out by a qualified
electrician!
Electric tools in need of repair can be
sent to an authorised service center in
12. Technical Specifications
Mains voltage
Frequency
Rated output
Rated current
Fuse protection min. (time-lag or L-type circuit breaker)
Running capacitor
Rated speed
Pump capacity max.
Delivery head max.
Delivery pressure max.
Immersion depth max.
Standing water max.
Solids size max.
Temperature of the primed medium max.
Degree of protection
Degree of protection
Insulation class
Materials
Pump casing
Pump shaft
Impeller
Power cable (HO 7 RN-F)
Discharge port (AG=male, IG=female)
Dimensions (pump casing)
Height
Width
Diameter
Weight
Max. length of extension cable
2
at 3 x 1.0 mm
2
at 3 x 1.5 mm
your country. See spare parts list for
address.
Please attach a description of the fault to
the electric tool.
10. Environmental Protection
The packaging of the pump can be
100 % recycled.
Worn out power tools and accessories
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled.
These instructions are printed on chlo-
rine-free bleached paper.
lead cross-section
lead cross-section
ENGLISH
11. Available Accessories
For this equipment the following acces-
sories are available at specialist dealers.
3
Note:
Illustrations and stock numbers
can be found at the end of these instruc-
tions.
A
Adaptor C-connector
1 1/2" internal threads,
pipe nipple 1 1/2" x 300mm
V
230
Hz
50
W
1100
A
4.8
A
10
F
16
-1
min
2800
l/h
17000
m
9
bar
0.9
m
5
mm
50
mm
33
°C
40
IP 68
I
F
stainless steel
stainless steel
stainless steel
m
10
1 1/2" IG
mm
360
mm
210
mm
160
kg
10.6
m
30
m
50
11