WXD 2
WARNING!
Fig. 4
Fig. 5
PK Elektronik Vertriebs GmbH, E-Mail:
[email protected], Internet: www.pkelektronik.com
5 Starting up the device
Electric shock and risk of burns
Connecting the control unit incorrectly poses a risk of injury due to
electric shock and can damage the device. Risk of burns from the
soldering tool while the control unit is operating.
Read the enclosed instructions, the safety instructions included
in these operating instructions as well as the instructions for
your control unit all the way through and observe the specified
precautionary measures before putting the control unit into
operation.
Always place the soldering tool in the safety holder when not in
use.
Please observe the overview diagrams (Fig. 1 and Fig. 2).
Note
Only soldering tools with suitable connecting plugs can be
connected to the WXD 2 desoldering station.
For details of tools which can be connected to WXD 2, please refer
to the list of accessories on page 20.
1. Carefully unpack the device.
2. Insert compressed air hose with 6 mm outer diameter in the quick
action coupling for the compressed air connection (22). Provide
supply of compressed air with 600 kPa (87 psi) dry, oil-free
compressed air.
3. Connect the soldering tools as follows:
Insert the soldering tool with connector into the connecting socket
(9/15) on the control unit and turn clockwise to lock.
4. Place the soldering tool in the holder.
5. Check to make sure that the mains supply voltage matches that
indicated on the rating plate and that the mains power switch (21)
is off.
6. Connect the control unit to the mains supply (19).
7. Switch on the device at the mains power switch (21).
The start-up screen is shown on the display (see Fig. 4).
After switching on the device, the microprocessor carries out a self-
test and reads out the values of the parameters stored in the tool.
When a soldering iron is connected, the display shows the set
temperature (set-point, 31/35), the temperature units °C/°F (33), the
actual value (actual tool temperature) (34) and the saved fixed
temperatures (28/29/37/38).
The vacuum necessary for desoldering is activated by the integrated
finger switch on the soldering iron.
Warning
Working without a filter will irreparably damage the compressed air
converter. Cleaning and Replacing see page 18.
7-21