Switching in-
KF5 (left-hand
put
charging point)
Terminal
A1
Conductor
L
Terminals A2 (KF5) and A2 (KF6) are electrically in-
terconnected.
Configuration
In the web interface, navigate to "Load Manage-
ment" > "Local" and set the following parameters:
Left-hand charging point
Parameter
Energy management
from external input
Current limit for energy
management from ex-
ternal input
Right-hand charging point
Parameter
Energy management
from external input
(Connector 2)
Current limit for energy
management from ex-
ternal input (Connector
2)
The input "OPTO 1" is not assigned.
5.10 Networking the product
Only valid for the networkable product variants.
The products must be connected to a central router
or switch via an Ethernet cable (max. length 100 m)
in order to connect several products to form a net-
work. The wiring must be carried out in star topo-
logy.
22
KF6 (right-hand
charging point)
A2
A1
A2
-
L
N
Setting
u Select "Enable Opto
2".
Current value to which
the charging current is
reduced.
Setting
u Select "Enable Opto
2".
Current value to which
the charging current is
reduced.
Fig. 12: Ethernet connection
u Connect the central router or switch and the
Ethernet surge protector (1) via an Ethernet
cable (2).
u Also connect the other products to the router or
switch.
1
2