Cabinet
Construction
To eliminate the risk of burns or fire by
reaching over heated surface units, do not have cabinet
storage space above the range. If there is cabinet
storage space above range, reduce the risk by installing
a range hood that projects horizontally a minimum of
5"(12.7 cm) beyond the bottom of the cabinet.
Countertop
Preparation
The cooktop sides of the range fit over the cutout
edge of your countertop.
If you have a square finish (fiat) countertop,
no
countertop
preparation is required.
Formed front-edged
countertops
must have
molded edge shaved flat 3/4"(1.9
cm) from each
front corner of opening.
• Tile countertops
may need trim cut
back 3/4"(I .9 cm)
(I .9 cm) from
each front corner
and/or rounded
edge flattened.
314"
_._
cu!out
"B/wIdth
31 1/2
(81 cm)
__
Formed
or
tiled
countertop
_3/4"
"
trimmed
3/4" (1.9cm)
(1.9 cm)
back at from corners
of
I
countertop
opening.
Figure 2
• tf the countertop
opening
width
is greater
than
the minimum
cutout
width,
adjust the 3/4" (1.9
cm) dimension.
For countertop
of 29"
(73.7cm}
cutout
wide
opening:
You must clear 2V_J'
2_/_j '
(5.6 cm} from
front
of countertop
to fit
the range in the
11/4 ``
cabinet,
(3.2 cm)
p:
trimmed
1%"
(3,2
cm)
back
at front
corners
of countertop
opening
for
29"
cut
out wide
opening,
Figure
3
• Countertop
must be JeveL Place a level on the
countertop,
first side to side, then front to back. If the
countertop
is not level, the range will not be level.
The oven must be level for satisfactory baking results.
Provide
an adequate
Gas Supply
When shipped from the factory, this unit is designed to
operate on 4"(10,16
cm) water column (!.0 kPa) Natural
gas manifold pressure. A convertible pressure regulator is
connected to the range manifold and MUST be
connected in series with the gas supply line. If LP/
Propane conversion kit has been used, follow instructions
provided with the kit for converting the pressure
regulator to LP/Propane use.
Care must be taken during installation of range not to
obstruct the flow of combustion and ventilation air.
Forproper
operation, the maximum inlet pressure to the
regulator should be no more than 14"(35,56 cm) of
water column pressure (3.5 kPa). The inlet pressure to
the regulator must be at least I " (.25 kPa) greater than
the regulator manifold pressure setting. Examples: If
regulator is set for natural gas 4" (I O,! 6 cm) manifold
pressure, inlet pressure must be at least 5"(12.60 cm); if
regulator has been converted for LP/Propane gas
10"(25,4 cm) manifold pressure, inlet pressure must be
at least 11 "(27,9 cm).
Leak testing of the appliance shall be conducted
according to the instructions in step 4.
The gas supply line should be _/2" or 3A" I.D.
Seal the openings
Seal any openings in the wall behind the range and in the
floor under the range after gas supply line is installed.
the range to the gas supply
_mportant:
Remove all packing material and
literature from range before connecting gas and
electrical supply.
To prevent leaks, put pipe joint sealant on all external
pipe threads.
Your regulator is in location shown below.
Do not
allow
regulator to turn
on pipe when
tightening
fittings.
PRESSURE REGULATOR
Figure
4
LOCATION