_MR-07_MH-07.book Seite 25 Freitag, 16. September 2011 4:42 16
Kühlschrank
6
Installing and connecting the device
6.1
Removing the cooling unit (MR-07 only)
➤ Bend back the guard plate (fig. 3 1, page 3) slightly.
➤ Remove the two fastening screws (fig. 3 3, page 3) using a long Phillips
screwdriver.
➤ Remove the cable binder from the rolled up cable.
➤ Unroll the cable.
➤ With the help of another person, lift up the cooling unit and turn it in the
opposite coiling direction of the suction line (fig. 3 2, page 3), until the
suction line is unrolled.
6.2
Installing the device
The device is designed for ambient temperatures between –10 °C and
+55 °C. In continuous operation, the air humidity may not exceed 90%.
➤ Observe the following installation instructions for the place of installation:
– Avoid placing the device next to heat sources such as heaters, gas
ovens, hot water pipes, etc.
– Install the device in a dry, sheltered place.
– The device must be installed so that heated air from it can dissipate
easily. Therefore make sure there is adequate ventilation (fig. 4,
page 4).
No. in fig. 4,
page 4
1
2
3
4
➤ Fix the device with eight screws (fig. 5 1, page 4).
EN
Installing and connecting the device
Explanation
Hot waste air
Cold intake air
Condenser
With decorative panel 50 mm space at the top!
25