Idiomas disponibles

Idiomas disponibles

AKGD3060
gas downdraft
cooktop
installed
above
AOCS3040
in a standard
kitchen
cabinet
10%" x 33/8"vent location for 10" by 3U4"vent indicated in
black. Junction box location indicated in grey. Installation
specified is for a 36" cabinet height, 231/2"minimum
depth.
i
WARNING
To avoid property damage or personal injury,
information in these installations must be followed
exactly,
A--6" minimum
B--25/8 '' right of centerline
C--43/8 '' between top of countertop and top of duct cutout
D--20%" cutout depth
E--287/8 '' cutout width
F--3/4 '' from back of cooktop cutout to center of gas entry
into cooktop
G--43/4 '' from right side of cooktop cutout to center of gas
entry into cooktop
H--281/2 '' wall oven cutout width
1--271/4'' wall oven cutout height
J--41/2 '' from top of coutertop to top of wall oven cutout
C L-centerline
of cutout
Wall oven and gas cooktop must be installed on seperate
electrical circuits. Be certain to avoid interference
between the wall oven power supply and the gas supply
lines.
A
B
Oven and Cooktop
junction box
installed in
acent cabinet
D
H
\
ii
\
\
ii
/