Operating Sequence - Lamborghini Caloreclima FUTURIA 24 PLUS MB W TOP Manual Para La Instalación Y El Mantenimiento

Ocultar thumbs Ver también para FUTURIA 24 PLUS MB W TOP:
Tabla de contenido
OPERATING SEQUENCE (display only)
Button
ON/OFF
RIARMO/RESET
PROG./MODE
During boiler operation the first figure on the digital display indicates the sequence step while the
second gives the temperature of the water in the boiler.
E.g.
Step
Function
pause, no heat required
0
1
pre-ventilation
ignition
2
3
burner ignited (heating system mode)
4
burner ignited (hot water mode)
5
air pressure switch control
6
burner off (water temp. more than 5°C warmer than setting)
post-circulation pump in heating mode
7
8
post-circulation pump in hot water mode
burner off because of fault (see shutdown code)
9
Function
ON/OFF SWITCH
SUMMER/WINTER SWITCH
BOILER RESET
PROGRAM SELECTOR
(DISPLAY)
means that the unit is heating at a delivery temperature of around 80°C.
Button
SEQUENZA/STEP
MEMO/STORE
+
-
Function
SELECTS PARAMETERS TO BE
DISPLAYED
ENTERS DATA
INCREASES SETTING
DECREASES SETTING
HOT WATER ADJUSTMENT
0-60°C
44
Tabla de contenido
loading

Tabla de contenido