Installation instructions

SVM 4001K-A / 4001K-C
Standstill monitoring for 1- and 3-phases motor without sensor
system
Device versions
SVM 4001K-A DC 24 V
R1.188.4020.0
with screw terminals,
plug-in
Doc. # BA000926 – 02/2017 (Rev. D)
(translation from original)
SVM 4001K-C DC 24 V
R1.188.4030.0
with spring-loaded
termi-
nals, plug-in
SVM 4001K-A / 4001K-C
Proper use
The equipment fulfills the requirements of the test principles
Category 4 / PL e according to EN ISO 13849-1:2008 + AC:2009
SIL CL 3
according to EN 62061:2005 + AC:2010 +
SIL3
according to
and can be used in applications till category 4 / PL e according
to EN ISO 13849-1 and SIL 3 according to EN 62061 / EN
61508.
Drives of machine tools without movement sensor systems can
be monitored with standstill monitoring SMV 4001K.
The output contacts of the equipment open, if the drive moves
or there is a failure in the system.
The output contacts are potential-free NO contacts. They can
be used to lock a safety cover or for an emergency stop func-
tion.
The standstill monitoring SVM 4001K can be used in safety
function circuit according to VDE 0113 T1. It can be mounted
at a 35mm DIN rail.
In dependence of the external circuit maximal category 4 / PL e
can be arrived according to EN ISO 13849-1 respectively SIL 3
according to EN 61508.
I M P O R T A NT NO T I C E
The described product has been developed as a part of a
safety system.
The system includes sensors, evaluation units, control units
and a concept for safe switch-off. The manufacturer is in
charge to ensure the correct functionality of the entire system.
The manufacturer is in charge to check and to prove the effec-
tiveness of the safety concept.
Any modification at the safety parameters or the safety con-
cept itself requires to re-prove the effectiveness of the safety
concept.
Wieland Electric cannot guarantee properties of systems that
not have been established in their own responsibility.
Wieland Electric also does not accept liability for any recom-
mendations derived from the following description. Claims
that go beyond the rights cited in the warranty are excluded.
A1:2013
EN 61508 Parts 1- 7:2010
EN 8