11 Technical data
Supply voltage
Motor protection
Type of protection
Winding category
Temperature category
Media temperature
Ambient temperature
Max. operating pressure
Noise
Leakage current
Power consumption
when pump switched off
Performance factor cos-
phi
EMV (electromagnetic
compatibility)
1×230 V ±10%, 50/60 Hz, PE
External motor protection is not required
IPX4D (EN 60529)
Insulation category F
TF110 (EN 60335-2-51)
+15 °C bis +110 °C (ModulA... RED)
–10 °C bis +110 °C (ModulA... GREEN)
+15 °C bis +85 °C (ModulA... BLUE)
0 to 40 °C
In transportation: –40 °C to +70 °C
The maximum operating pressure is given on the nameplate:
PN 6: 6bar
PN 10: 10bar
PN 16: 16bar
The noise pressure level generated by the pump depends on the
power consumption.
Pump size
25-4/6/8/10/12
32-4/6/8/10/12
40-4/6
40-11, 50-11
The mains filter of the pump causes a leakage current
to the earth of <3.5 during operation
<3W
The ModulA has an integrated performance factor correction filter
(PFC). This ensures that cos-phi is always between 0.98 and 0.99
and is therefore kept very close to the ideal value 1.
EN 55014-1:2006, EN 55014-2:1997,
EN 61000-3-3:2008 and EN 61000-3-2:2006
Max. noise pressure level dB(A)
39
50
english
31
|