2. Install the power supply cable by loosening the cable
clamp screw and the three wire contact screws
L-N-
.
Connect the wires to the corresponding terminals: the Blue
L
N
Connecting the supply cable to the mains
Install a standardised plug corresponding to the load
indicated on the data plate (see table).
The appliance must be directly connected to the mains using
an omnipolar switch with a minimum contact opening of 3
mm installed between the appliance and the mains. The
switch must be suitable for the charge indicated and must
comply with current electrical regulations (the earthing wire
must not be interrupted by the switch). The supply cable
must be positioned so that it does not come into contact
with temperatures higher than 50°C at any point (the back
panel of the oven, for example).
! The installer must ensure that the correct electrical
connection has been performed and that it is fully compliant
with safety regulations.
Before connecting the appliance to the power supply, make
sure that
• The appliance is earthed and the plug is compliant with
the law.
• The socket can withstand the maximum power of the
appliance, which is indicated on the data plate.
• The voltage is in the range between the values indicated
on the data plate.
• The socket is compatible with the plug of the appliance.
If the socket is incompatible with the plug, ask an
authorised technician to replace it. Do not use extension
cords or multiple sockets.
! Once the appliance has been installed, the power supply
cable and the electrical socket must be easily accessible.
! The cable must not be bent or compressed.
! The cable must be checked regularly and replaced by
authorised technicians only (see Assistance).
! The manufacturer declines any liability should these
safety measures not be observed.
wire to the terminal marked
(N), the Brown wire to the
terminal marked (L) and the
Yellow/Green wire to the
terminal marked
(see
diagram).
3. Secure the cable by
fastening the clamp screw.
4. Close the cover of the
terminal board.
APPLIANCE SPECIFICATIONS
width 43.5 cm
Dimensions*
height 32,4 cm
depth 41.5 cm
Volume*
59 l
width 45.5 cm
Dimensions**
height 32,4 cm
depth 41.5 cm
Volume**
62 l
voltage: 220 - 240 V~ 50/60 Hz or
Electrical
50 Hz (see data plate)
connections
maximum power absorbed
2800 W
Directive 2002/40/EC on the label
of electric ovens. Standard EN 50304
ENERGY
Declared energy consumption
LAB EL
for Forced convection Class –
heating mode:
ECO.
* Only for models with drawn rails.
** Only for models with wire rails.
GB