Specification
Rated voltage
Rated frequency
Capacity
Power input
Required fuse
Cutting shaft
rotation speed
Motor protection class
Motor duty type
Specification
Rated voltage
Rated frequency
Capacity
Duty type
OPERATING CONDITIONS
Working zone
Specification
Temperature range
Relative air humidity,
maximum
Conditions
The data define the sound level of the noise exposure at the workplace of the operator and sound power level of the
machine tool.
The emission values meet standards EN ISO 3744, EN 12418 and Directive 2005/88/EC.
82
Value
Unit
230
400
V
50
50
Hz
2,2
2,2
kW
13
6,3
A
16
16
A
2800
2800
U/min
IP55
IP55
S6
S6
Value
Unit
230
V
50
Hz
55
W
S2
Value
Ambient temperature 5-45
60 (without condensing)
Only operate the machine tool in the dust-free environment!
Avoid direct impact of dampness, dust and frost.
Do not operate in strong electric and magnetic fields!
Do not operate the machine tool in explosive atmosphere!
Specification
Value
Water tank
30
Diamond blade
350
Bore
25,4
Flange Ø
90
Vibration level
2,3
Measuring tolerance
Vibration level
0,2
Unit
°C
%
Unit
l
mm
mm
mm
m/s2
m/sec^2