Connecting the control system
B, C
NOTE
The unit will be damaged, if water enters the plug connector.
Connect the plug connector or place the protective cap on it.
Ensure that the rubber seal is clean and fits exactly.
If the rubber seal is damaged, it must be replaced. When the plug connector is disconnected,
the rubber seal must be replaced if it is older than 2 years.
Always secure the plug connector or the protective cap with the two screws.
Submerged installation of the pump
Connecting
D
Connect the pump according to the desired installation variant. (→ Installation variants)
• Ensure that the intake-side hose (IN) does not have a smaller diameter than the pressure-side
hose (OUT).
• The larger the hose diameter, the smaller the friction losses in the lines and the better the
flow rate.
• The hose diameter must not be limited unnecessarily by a hose sleeve. Shorten the hose
sleeve based on the hose diameter, if necessary.
Do not plug the power plug into the socket yet!
Installation
E
• Place the pump horizontally on a stable surface.
• Ensure secure and stable positioning of the pump.
• For muddy or soiled water, we recommend installing the pump or intake-side components
(skimmer, satellite filter, base outlet, etc.) above ground level. This decreases intake of parti-
cles and increases the service life of the impeller unit.
• Only operate the pump when it is covered in at least 10 cm of water. Otherwise it may draw in
air.
The pull rope allows you to simply pull the pump from the water.
− Fasten the pull rope on the bottom filter casing through the round openings and make a
knot.
16