Li-Ion batteries is composed of a mixture of liquid organic carbonates and lithium salts.
• Contents of opened battery cells may cause respiratory irritation. Provide fresh air.
If symptoms persists, seek medical attention.
WARNING:
Charge the battery packs only in PORTER-CABLE chargers.
•
• DO NOT splash or immerse in water or other liquids. This may cause premature cell failure.
• Do not store or use the tool and battery pack in locations where the temperature may
reach or exceed 105°F (40˚C) (such as outside sheds or metal buildings in summer).
WARNING:
case is cracked or damaged, do not insert into charger. Do not crush, drop or damage
battery pack. Do not use a battery pack or charger that has received a sharp blow, been
dropped, run over or damaged in any way (i.e., pierced with a nail, hit with a hammer,
stepped on). Damaged battery packs should be returned to service center for recycling.
WARNING:
can contact exposed battery terminals. For example, do not place battery in aprons,
pockets, tool boxes, product kit boxes, drawers, etc., with loose nails, screws, keys, etc.
Transporting batteries can possibly cause fires if the battery terminals
inadvertently come in contact with conductive materials such as keys, coins, hand
tools and the like. The US Department of Transportation Hazardous Material
Regulations (HMR) actually prohibit transporting batteries in commerce or on airplanes
(i.e., packed in suitcases and carry-on luggage) UNLESS they are properly protected
from short circuits. So when transporting individual batteries, make sure that the battery
terminals are protected and well insulated from materials that could contact them and
cause a short circuit. NOTE: Li-Ion batteries should not be put in checked baggage.
STORAGE RECOMMENDATIONS
1. The best storage place is one that is cool and dry away from direct sunlight and
excess heat or cold.
2. Long storage will not harm the battery pack or charger.
CHARGING PROCEDURE
PORTER-CABLE chargers are designed to charge PORTER-CABLE battery packs.
Charge times are: PCC690L in 40-100 mins., PCC691L in 70-200 mins. and PCC695L
in 180-300 mins. depending on the pack being charged.
1. Plug the charger into an appropriate outlet before inserting the battery pack.
2. Insert the battery pack into the charger.
3. The LED will flash indicating that the battery is being charged.
4. The completion of charge is indicated by the LED remaining on continuously.
The pack is fully charged and may be used at this time or left on the charger.
Recharge discharged batteries as soon as possible after use or battery
life may be greatly diminished. For longest battery life, do not discharge
batteries fully. It is recommended that the batteries be recharged after each use.
CHARGER DIAGNOSTICS
This charger is designed to detect certain problems that can arise with the battery packs
or the power source. Problems are indicated by one LED flashing in different patterns.
Bad Battery
The charger can detect a weak or damaged battery. The LED flashes in the pattern
indicated on the label. If you see this bad battery blink pattern, do not continue to
charge the battery. Return it to a service center or a collection site for recycling.
Hot/Cold Pack Delay
When the charger detects a battery that is excessively hot or excessively cold,
it automatically starts a Hot/Cold Pack Delay, suspending charging until the
battery has normalized. After this happens, the charger automatically switches to
the Pack Charging mode. This feature ensures maximum battery life. The light
flashes in the pattern indicated on the label.
Problem Power Line
When the charger is used with some portable power sources such as generators
or sources that convert DC to AC, the charger may temporarily suspend
operation. The LED flashes in the pattern indicated on the label. This indicates
that the power source is out of limits.
Burn hazard. Battery liquid may be flammable if exposed to spark or flame.
Never attempt to open the battery pack for any reason. If battery pack
Fire hazard. Do not store or carry battery so that metal objects
7