Intended use
This device is intended to be used for firing pins
(fasteners) into concrete, full block calcium silicate,
full bricks and steel using the original Würth system
parts.
Any other use is considered improper.
The user is responsible for damage resulting from
improper use.
+49 1805-60 65 69 (14 Cent/min).
Device Data
Art.
Firing power (max.)
Pin length x pin - Ø (max.)
Magazine capacity
Dimensions (height x length
x width)
Weight
Gas cartridge item no. 0864 900 500
Capacity
Substance
Hazard class
Max. ambient temperature 50°C
Energy reserve
Mains adapter
Input voltage / current
Output voltage / current
Charging time
- Discharging the battery
- first use
Battery
Nominal voltage
Capacity
Ambient temperature
Energy reserve with fully
charged battery
144
The device has a combustion drive with explosive
gas mix. By ignition of the gas mix, the piston is
actuated and drives in the pin. Exhaust gas and
noise emissions, which may be hazardous to health,
are generated during the combustion process.
Adhere to the stipulated safety instructions.
Charge the battery
The battery must be charged for 24 hours prior to
0864 90 3
first use and when it has not been in use for a longer
period of time to achieve full capacity.
1000/h
40 x 3.7 mm
42 pins / 22 pins
365 x 435 x 124
3 The charging process starts as soon as the
mm
3.7 kg
80 ml
Indications
- Propylene
The charger is equipped with red and green LED
- But-1-ene
indicators
that show the charging state:
2.1 UN 1965
3 Charger is ready to operate. The battery is fully
approx. 1100
firing processes
3 The charging process is activated. The battery is
100–
240 V AC / 0.4 A
3 Temperature fault; battery is too hot and cannot
10 V/ 0.8 A
120 min
3 Charging not possible; battery defective.
24 h
NiMH
Battery charging state / maintenance
6 V DC
indication
1.5 Ah
The indication [4] on the device allows monitoring
5 - 50 °C
of the battery charging state and indicates if mainte-
nance is needed.
approx. 3000
firing processes
Method of functioning
Battery and charger (fig. II)
To remove the battery [6] from the device, fully
push the two release buttons [5].
Plug the power plug into the socket and the
charging plug into the socket of the charger.
battery [6] is set in the charging cradle. The
battery warms up during charging. This is a
normal process.
Green LED illuminates:
charged.
Red LED illuminated:
being charged.
Red and green LED flash in turn:
be charged.
• Remove the battery and allow it to cool
down.
Red and green LED flash simultaneously:
• Replace battery.
It illuminates in red if the battery needs to be
charged.
It flashes in red if the device must be sent to
Würth masterService for maintenance.