Mitsubishi Electric PLA-A-EA Serie Manual De Instrucciones página 11

Idiomas disponibles

Idiomas disponibles

3. Operation
Manual vane angle (Wired remote controller)
Operation
Vane·Louver·Vent. (Lossnay)
High power
Comfort
Main menu: RETURN
Cursor
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
Comfort
Manual vane angle
3D i-See sensor
Setting display: SELECT
Cursor
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
Manual vane angle
Ref. address
Unit No.
Identify unit Check button
Input display:
SELECT
Cur.
Address
Check
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
Manual vane angle
Ref. address
Unit No.
Vane
4-way
/2-way
Input display:Angle button
Cur.
Cursor
Angle
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
1 Select "Comfort" from the Opera-
tion menu, and press the [SELECT/
HOLD] button.
2 Select "Manual vane angle" with
the [F1] or [F2] button, and press
the [SELECT/HOLD] button.
3 Move the cursor to "Ref. address"
or "Unit No." with the [F1] button
to select.
Select the refrigerant address
and the unit number for the units
to whose vanes are to be fixed,
with the [F2] or [F3] button, and
press the [SELECT/HOLD] but-
ton.
• Ref. address: Refrigerant address
• Unit No.: 1, 2, 3, 4
Press the [F4] button to confirm
the unit.
Select "Vane" with the [F1] button.
Select "4-way" or "2-way" with the
[F2] or [F3] button, and press the
[F4] button.
Manual vane angle
Select: SELECT
Outlet
Angle
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
Manual vane angle
Setting
Note:
Do not set the draft reduction in an environment with high humidity.
Otherwise, condensation may form and drip.
Vane setting
No setting
Step 1
Step 3
Step 4
Draft
All outlets
reduction*
Press the [SELECT/HOLD] button to save the settings.
A screen will appear that indicates the setting information is being trans-
mitted.
The setting changes will be made to the selected outlet.
The screen will automatically return to the one shown above (step 5)
when the transmission is completed.
Make the settings for other outlets, following the same procedures.
If all outlets are selected,
the unit goes into operation.
Navigating through the screens
• To go back to the Main menu ................ [MENU] button
• To return to the previous screen .......... [RETURN] button
4 The current vane setting will ap-
pear.
Select the desired outlets from
"1","2", "3", "4", or "1, 2, 3, 4 (all
outlets)" with the [F1] or [F2] but-
ton.
Press the [F3] or [F4] button to go
through the following options and
select the desired setting.
* Draft reduction
The airflow direction for this set-
ting is more horizontal than the
airflow direction for the "Step 1"
setting in order to reduce a drafty
feeling. The draft reduction can
be set for only 1 vane.
Step 2
Step 5
will be displayed the next time
en
10
loading