Hitachi Koki DV 14DCL Manual De Instrucciones página 12

Taladro de percusion a bateria
Ocultar thumbs Ver también para DV 14DCL:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

English
3.
Charging
When the battery is connected to the battery
charger, charging will commence and the charge
status lamp will light in red. (See Table 2)
Before
Charge
charging
status
lamp (RED)
While
charging
Charging
complete
Charging
impossible
Overheat
Overheat
standby
lamp
(GREEN)
NOTE: When standby for cooling battery, UC18YRL cools the overheated battery by cooling fan.
Regarding the temperature of the rechargeable
battery.
The temperatures for rechargeable batteries are
as shown in the table below, and batteries that
have become hot should be cooled for a while
before being recharged.
Rechargeable
batteries
Ni-Cd batteries
Ni-MH batteries
Li-ion batteries
4.
Disconnect battery charger from the receptacle.
CAUTION:
Do not pull the plug out of the receptacle by
pulling on the cord.
Make sure to grasp the plug when removing from
receptacle to avoid damaging cord.
5.
Remove the battery from the battery charger.
Supporting the battery charger with hand, pull out
the battery from the battery charger.
12
Indications of the lamp
Blinks
Lights for 0.5 seconds. Does not light for 0.5
(RED)
seconds. (off for 0.5 seconds)
Lights continuously
Lights
(RED)
Blinks
Lights for 0.5 seconds. Does not light for 0.5
(RED)
seconds. (off for 0.5 seconds)
Flickers
Lights for 0.1 seconds. Does not light for 0.1
(RED)
seconds. (off for 0.1 seconds)
Lights
Lights continuously
(GREEN)
Table 3
Temperatures at which the
battery can be recharged
23°F – 131°F (–5°C – 55°C)
23°F – 122°F (–5°C – 50°C)
32°F – 122°F (0°C – 50°C)
NOTE:
If the charge status lamp flikers in red, pull out the
plug from the receptacle and check if the battery
is properly mounted.
When the battery is fully charged, the charge status
lamp will bilink in red slowly. (At 1-second
intervals) (See Table 2)
Table 2
CAUTION:
Repair is required if the receptacle is not secured
properly or the power cord does not stay in the
receptacle. Consult your electrician. Using the
charger in this condition may lead to fire.
If the charge status lamp is blinking red rapidly
(in 0.2 second intervals), check that the hole for
connecting the battery is not obstructed. Remove
any obstructions. If no obstructions are found, the
battery or charger may be malfunctioned. Return
both to your place of purchase.
If the charge time lamp does not light when the
power cord is connected to the receptacle,
disconnect the power cord, and check that the
battery is attached correctly.
The battery retains heat when used or left for
prolonged periods in direct sunlight. In this state,
the overheat lamp lights green, and the battery
cannot be charged immediately. Leave the battery
inserted in the charger, and charging will
commence when the battery cools down.
If the lamp goes out while charging, disconnect
the power cord, and leave for 3 to 5 minutes before
reconnecting. If the problem persists, call for
repairs.
Leave 5 minutes between charging batteries as
the charger may overheat leading to malfunction.
Malfunction in the
battery or the charger
Battery
overheated.
Unable
to
charge
(Charging will commence
when battery cools).
Tabla de contenido
loading

Este manual también es adecuado para:

Dv 18dclDv 14dvcDv 18dvc

Tabla de contenido