7.4.
Error messages
Display
Description
Err. 0
Internal data error
Temperature increase too low despite
heating at full power:
• Kiln does not heat or heats too slowly
Err. 1
• The kiln temperature is not increasing
as required.
The kiln has been on full power for 15
minutes, but the temperature has not
increased by at least 2 °C.
Err. 2
Thermocouple or wiring for thermocouple
disconnected
Err. 3
Thermocouple with reversed polarity
Kiln cools down too slowly:
Kiln does not cool down or cools down
Err. 4
too slowly.
The kiln has been on zero power for 30
minutes, but the kiln temperature has
not fallen by at least 1 °C.
Set kiln temperature exceeded:
Desired temperature
Below 100 °C
Err. 5
More than 100 °C but less
More than 200 °C but less
More than 600 °C
Err. 6
Maximum duration of firing process
exceeded
Err. 7
The maximum room temperature
exceeded
Overshoot allowed
+ 60 °C
+ 50 °C
than 200 °C
+ 30 °C
than 600 °C
+ 20 °C
Cause of error / Troubleshooting
Technical service required:
The controller cannot be repaired on site and
must be sent to the manufacturer for repair.
Kiln door or lid not completely closed.
Defective door switch
Door switch needs to be adjusted.
Heating element circuit open
Heating elements too old
Electrical power phase failure
Contactor failure
Get thermocouple and wiring checked.
Replace thermocouple if necessary.
Kiln temperature apparently below -40 °C
This is an installation fault.
Get wiring checked.
Contactor failure (contacts possibly welded)
Thermocouple disconnected or resistance too
high
• The kiln temperature has exceeded the desired
temperature by a preset limit.
• The cause of the over-temperature must be
determined.
• The contactor is not working (contactor
hangs/replace contactor).
• The duration of the firing process exceeds a
limit value set in the factory.
• Notes on Error 6:
⇒ The error is disabled at the factory.
⇒ If you want to set a maximum firing time,
please contact ROHDE Service.
The internal temperature of the controller has
exceeded a factory-set limit value.
Factory-set to 50 °C.
Possible causes:
­
Insufficient or faulty ventilation of the kiln
chamber
­
Operating location too small
­
Ventilation grille blocked
­
Exhaust air flap not closed
­
Controller mounted too close to the kiln
67 / 293 - EN -