Egg health and hygiene
To maximise fertility and to avoid contamination during the incubation period, please follow the directions below when col-
lecting eggs:
- Collect the eggs daily to avoid contamination or loss from breakage or damage, caused by hot or cold temperatures (winter
and summer periods).
- Clean hands before and after egg collection with anti-bacterial soap.
- LOAD EGGS STORED NOT MORE THAN 7- 8 DAYS AND NOT LESS THAN 3 DAYS FROM LYING.
- BEFORE INCUBATION, THE EGGS MUST BE STORED IN A SPECIFIC EGG-BASKET (IN VERTICAL POSITION WITH THE
AIR-SPACE FACED UPWARDS) WITH TEMPERATURE BETWEEN 14 – 16 °C.
- Do not mark the eggs with felt-tip pens – use only pencil
MODEL "COSMO"
POWER SUPPLY
POWER CONSUMPTION
DIMENSIONS
NET WEIGHT
EGGS CAPACITY
SPECIE
HEN
QUAIL
TURKEY
GUINEA FOWL
PARTRIDGE
GOOSE
OSTRICH (CAMELUS)
CARE AND MAINTENANCE
In order to achieve the best operation and longest life of the machine, follow the following precautions:
• do not expose the machine to outdoor elements
• do not place machine in hot, wet or cold rooms;
• avoid bad handling during moving that can cause breakages inside the machine and affect its working;
• disconnect the power plug before cleaning the machine;
• Do not accidentally pull out the power cable when moving the machine.
IMPORTANT: take out the plug from the socket by holding the plug and not the power cable; use only a mains power socket
or surge-protected extension lead.
• for cleaning and disinfection please follow the advice as follows:
HOW TO CLEAN THE INCUBATOR:
For a good hygiene during the incubation, it is recommended to clean the machine before and after its use;
Use a wet cloth on the machine with a light disinfectant; do not use solvents that can damage the machine cabinet;
Clean the base of the machine with a normal domestic detergent.
DISINFECTION with GLUTARSAN: at the end of incubation, after cleaning, it is recommended to proceed to an accurate
disinfection of the internal parts of incubators and hatchers with Glutarsan, a disinfectant with bactericidal, yeasticidal and
virucidal action particu larly indicated to prevent common diseases in poultry species such as avian flu. You can request it
directly to FIEM Incubators com pany which successfully tested it on its own incubators and took care of creating a small
100 ml package with vial for occasional use.
ADVICE: after cleaning the machine, please keep it working without eggs & water for at least two hours (with the door
semi-closed), in order to dry the humidity which has accumulated during the incubation period... This will ensure the correct
machine operation for the next use.
INSTRUCTIONS FOR LIGHT BULB REPLACEMENT:
a) Buy small bulb only (pear shape) of 15W with an E14 screw fitting or led light of 3-5W (220V);
b) Remember to switch off the machine and disconnect the power cable from the current socket and leave the lamp
cooling in order to avoid any scalding;
c) Use a star screwdriver and unscrew the screw;
d) Take out the wire mesh on the bottom of the machine;
e) Unscrew the broken lamp in anti-clockwise direction (be careful with those exploded or broken);
f) insert the new lamp, screwing it carefully in clockwise direction;
g) Put the mesh back again inside, screwing carefully the screw.
20
V/Hz
Watt.
mm
Kg
Hen - Mallard
Pheasant
Partridge - Quail
Turkey - Duck
Goose
INCUBATION PERIOD OF THE DIFFERENT SPECIES
DAYS
21
16-17
28
26
23-24
30
42
220-240V 50/60Hz
252+1,5
640 x 530 x 400
150-180
SPECIE
PEKIN DUCK
WILD DUCK
BARBARY DUCK
RED LEG
PHEASANT
BOB WHITE
9,8
70-72
96-104
62-64
30-36
DAYS
27-28
25-26
34-35
23-24
24-25
22-23