5-13
11
4-6
70
5.6
Easy Alu function
The Easy Alu function automatically recognises the
Alu required by the operator and the rim dimension
parameters.
The machine presents only the possible Alus (Fig.
5-13), in relation to the contact points selected by the
operator.
Note:
Thanks to the Easy Alu function after the operator
has taken the rim measurements using the gauges,
in the weight application positions the machine
electronically processes the wheel data and
automatically proposes an ALU mode, on the basis
of the contact positions chosen by the operator.
Suggestion
Even if it is available, we suggest you do not select
the ALU mode manually for normal balancing
procedures. Changing the ALU in fact, if carried out
before or after a run, cancels the use of the Real
Data obtained with the Easy Alu procedure.
The machine proceeds by processing the Real Data
as if they were Nominal Data (entered manually).
Balancing will not be as precise and no more ALU
P modes will be available even if selected.
Application:
— Extract and rest the Gauge Head on the rim (
7.0.1.3) and keep it in position until an audible signal
is heard.
— Move the gauge to the idle position.
At this point you can proceed with a measuring run,
or fi rstly you can change the Alu mode suggested
by the machine, using the "Easy Alu Toggle" key.
5.6.1
"Easy Alu Toggle" function
Automatic correcting the Alu proposed
Depending on the gauge contact points on the rim,
the machine has interpreted a probable Alu mode
required by the user. Every time the Alu presented
by the machine does not correspond exactly to the
one required it can be corrected using the "Easy Alu
Toggle" function.
— Press the "Easy Alu Toggle" key (11, Fig. 4-6) if
you want the alternative Alu mode to that suggested
for the rim being worked on.
The position for adhesive weights can be precisely
located with the Auto-Stop-System ASS after the
measuring run.
F