POWERING UP YOUR SPA
Once the spa is properly wired and fi lled with water, the spa power can
be turned on and Start-up chemicals added.
1. Turn on RCD breaker. If breaker trips immediately checkNeutral and
Ground Wire connections. Upon initial power up,4 sets of numbers
fl ash on the LED display of the topside Console. The last number in the
sequence is the incoming power meter which can be used to verify that
the spa is wired correctly.
2. The spa begins an automatic priming routine which will last 6 minutes
("Pr" is on the LED display).
3. The priming routine will automatically run each spa pump to prime.
When the "Pr" is displayed, press any PUMP button to prime that pump
or wait for the priming
routine to turn on the Pump. IMPORTANT: To avoid pump damage, do
not run pumps for more than 1 minute without moving water. If no water
is moving, turn the power off and perform air lock procedure.
4. The Topside Console display fl ashes "100F" then press "--F" for
approximately 2 minutes to determine water temperature as it fl ows
through the heater.
5. The default pre-set temperature is 36.5°C. The last measured tempe-
rature is constantly displayed on the LCD readout. This temperature will
be current only when the pump has been running for at least 2 minutes.
Set the desired temperature between 80-104°F (26- 40°C) by pressing
10
starting your spa
the temp button(s). If the water temperature is below the set temperature,
the spa's heater and heat indicator light will turn on. All features of the
Topside Console will be available.
The spa will heat approximately 1° every 30 minutes per 1,000 litres.
6. Check for leaks! Although spas are fully checked at the factory, ship-
ping & delivery might cause a leak. Remember to pay particular attention
to barrel unions adjoining the heater. Contact your local dealer directly if
there is a problem.
If your new spa pump does not prime (fl ow) on the initial start-up you
may be experiencing an "air lock". This normal occurrence can be easily
corrected by loosening the plumbing union on the suction side of the
Jet or Circulation Pump until water fl ows into the pump and all air is
expelled.
PRESS BUTTONS SLOWLY FOR FIRST RUN WHEN STARTING UP
ONCE PR EXITS, SET TEMPERATURE ON SPA (SEE SPA OPERATION SEC-
TION FOR DIFFERENT SPA TOPSIDES)