Fireplace Installation
CAUTION: Ensure installation
does not allow fireplace to be in
direct contact with building vapor
barrier or insulation and meets all
local building code.
!
NOTE: A dedicated, properly
fused 13 Amp circuit is required,
rated for the appropriate voltage
(230-240V).
WA R N I N G : C o n s t r u c t i o n
and wiring must comply with
local building codes and other
applicable regulations to reduce
the risk of fire, electric shock
and injury to persons.
WARNING: To reduce the risk
of fire, electric shock or injury to
persons, always use a licensed
electrician.
WARNING: To reduce the risk of
fire, do not store or use gasoline or
other flammable vapors or liquids in
the vicinity of the heater.
1. Select a location that is not
susceptible to moisture and is
away from drapes, furniture and
high traffic.
2. Unpack
the
hardware from the box.
!
NOTE: Leave the front glass
and
partially
safely, in the box until the time you
fireplace
reflective
glass,
are ready to install it.
3. Store the fireplace in a safe,
dry and dust free location until
you are ready to install the
fireplace.
Installation
CAUTION: Two people will be
required for various steps of
this procedure.
This design of this unit allows three
options for installation: partial
recess, flush mounted or sub-
surface mounted.
CAUTION:
mounting should be limited to ½
in. (12 mm) to ensure adequate
air flow of heated air out of the
firebox area.
1. Prepare a wall with a framed
opening of 16 in. (40.6 cm)
high,
• XLF50 - 50 ⅝ in. (128.7 cm)
• XLF60 - 60 ⅝ in. (154.0 cm)
• XLF74 - 74 ⅝ in. (189.7 cm)
• XLF100 - 100 ⅝ in. (255.7
cm) wide, with a bottom sill
that is a minimum of 4 in.
and
(10.2 cm) deep. The sill can
be constructed to support the
front of the unit to allow the
power supply wires to easily
Sub-surface