horizontal fixed cursor so that the object is positioned between the cursors. An automatic recalculation of the
distance to the target occurs simultaneously with this movement.
If the distance is not determined within 10 seconds, the information disappears from the display.
џ
Go to the relevant item on the menu to select a unit of measurement (metres or yards).
џ
A distance value is rounded up or down before appearing on the display to 5 metres for longer distance
џ
readings and 1 metre for shorter distance readings.
To exit the rangefinder mode, press the Menu button (3) briefly, or wait 10 seconds for automatic exit.
џ
DISPLAY OFF FUNCTION
This function disables the transfer of images to the display, reducing the intensity of its illumination to a
minimum. This helps prevent inadvertent unmasking. The device will continue to function.
When this function is in use, the device switches to standby mode, which allows it to be quickly turned off, if
џ
necessary.
When the device is switched on, press and hold the ON button (5). The display will disappear and the message
џ
'Display off.' will appear.
To switch on the display, press the ON button (5) briefly.
џ
When the ON button (5) is held, the display will show 'Display off.' and a countdown.
џ
Then the device will turn off.
PiP FUNCTION
PiP (Picture in Picture) enables you to view a magnified digital zoom image
in a separate 'window' simultaneously with the main image.
Enabling/disabling the PiP function:
Press and hold the Menu button (3) to enter the main menu.
џ
Select the 'PiP Mode' option
џ
PIP
A short press of the Menu button (3) switches the mode on/off.
џ
Press and hold the Menu button (3) to exit the main menu.
џ
The enlarged image is displayed in a separate window using the full optical zoom value.
џ
To alter the zoom ratio in the PiP window, briefly press the UP button (4).
џ
The remaining image is displayed with the optical zoom value which corresponds to the value of the x1.0
џ
coefficient.
When the PiP is turned on, you can control the discrete and smooth zooms. In this instance, the full optical
џ
magnification value will appear only in the separate window.
When PiP is turned off, the image is displayed with the optical zoom value set for the PiP mode.
џ
PiP FUNCTION
The principal display mode for an observed image is 'Hot White'.
To enable the alternative palettes described below and to toggle between them, briefly press the DOWN
џ
button (2).
A long press of the DOWN button (2) activates the 'Hot White' mode.
џ
Colour palettes:
Hot White
A black and white palette (cold temperature corresponds to black, and hot temperature to white).
Hot Black
A black and white palette (cold temperature corresponds to white, and hot temperature to black).
Hot Red
Rainbow
Ultramarine
Sepia
USB CONNECTION
Connecting the device to a computer used as an external power source.
Connect one end of the USB cable to the device's microUSB connector (8) and
џ
the other end to the port on your computer.
Switch the device on by pressing the ON button (5) (the computer will not
џ
detect the device if it is turned off).
The device is detected automatically by the computer and no installation of drivers is required.
џ
When this option is selected, the computer is used by the device as an external power source. An icon will
џ
appear in the status bar
The battery installed in the device will not be charged.
џ
When disconnecting the USB from the device when connected in Power Mode, the device will continue to
џ
function on battery power, if present and sufficiently charged.
If a video was being recorded at the time of connection, the recording will cease and be saved.
џ
TECHNICAL INSPECTION
A technical inspection of the device is recommended before each use. Check:
The external appearance of the device (there should be no cracks in the casing).
џ
The condition of the lens and eyepiece (there should be no cracks, greasy spots, dirt or other deposits).
џ
The condition of the rechargeable battery (this should be charged) and the electrical contracts (there should
џ
be no presence of salts or oxidation).
The controls should be in working order.
џ
6.9x
MAINTENANCE
Maintenance should be carried out at least twice a year and consist of the following actions.
џ
Wipe the external surfaces of metal and plastic parts free of dust and dirt with a cotton cloth Silicone grease
џ
3.1x
may be used for this.
Clean the electrical contacts of the battery and battery slot on the unit using a non-greasy organic solvent.
џ
Check the glass surfaces of the eyepiece and the lens. If necessary, remove dust and sand from the lenses
џ
(preferably using a non-contact method). Cleaning of the external surfaces of the optics should be done with
substances designed specially for this purpose.
TROUBLESHOOTING
This table lists all the problems that may arise when operating the device. Carry out the recommended checks
and repairs in the order shown in the table. If a defect should occur that is not listed in the table, or if it is
impossible to repair the defect yourself, the device should be returned for repair.
. The device will continue to function and all functions are available.
USB connection
Use as power
6