Sonel CMP-400 Manual De Uso página 53

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Duty Cycle
Range & Resolution
10.0...94.9%
Pulse width: 100µs...100ms, Frequency: 30Hz...15kHz;
Sensitivity: 30...5kHz:10Vrms min. 5kHz...15kHz:40Vrms min.
Temperature measurement
-20.0...760.0C
-4.0...1400.0F
* probe (K type) accuracy not included
Other technical data
a) Measurement category in acc. with EN 61010-1 .................................... III 600V
b) Ingress protection in acc. with EN 60529 ..................................................... IP40
c)
Pollution degree ................................................................................................. 2
d) Power supply ............................................................................... one 9V battery
e) Clamp size ............................................................ Opening 30mm (1,2") approx
f)
Diode test.......................................................................... I=0.3mA, U
g) Continuity test ................................................ I<0,5mA, sound signal for R<50Ω
h) Overrange indication ...................................................................... OL displayed
i)
Measurements rate.......................................................... 2 per second, nominal
j)
Input impedance ...................................................................... 10MΩ (V AC/DC)
k)
Display .................................................................................... LCD, 4000 counts
l)
Dimensions ............................................................................. 197 x 70 x 40 mm
m) Weigh .......................................................................................................... 183 g
n) Operating temperature .................................................. 5 to 40°C (41 to 104°F)
o) Storage temperature................................................... -20 to 60°C (-4 to 140°F)
p) Operating humidity .............................. max 80% up to 31°C (87°F) decreasing
.......................................................................... linearly to 50% at 40°C (104°F)
q) Storage humidity ......................................................................................... <80%
r)
Max. operating altitude ...................................................... 2000meters (7000ft.)
s)
Auto OFF .............................................................................. approx. 30 minutes
t)
Compliance with the requirements specified in the following normsEN 61010-1
.................................................................................................. EN 61010-2-032
u) Quality standard ................................................................................... ISO 9001
Range
CMP-400 – USER MANUAL
Basic Accuracy
unspecificated
Basic uncertainty *
± (3% m.v. + 5C)
± (3% m.v. + 9F)
=1.5V DC
0
51
Tabla de contenido
loading

Tabla de contenido