Hilti STR 4-22 Manual De Instrucciones Original página 27

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 62
3.4.2
Indicators showing the battery's state of health
To check the battery's state of health, press the release button and hold it down for longer than three
seconds. The system does not detect a potential malfunction of the battery due to misuse, for example
battery dropped or pierced, external heat damage, etc.
Status
All LEDs show in sequence, followed by one (1)
LED showing constantly green.
All LEDs show in sequence, followed by one (1)
LED quick-flashing yellow.
All LEDs show in sequence, followed by one (1)
LED showing constantly red.
3.5
Function selector switch
3 functions can be selected by means of the function selector switch:
Explanation of symbols, function selector switch
Function
Meaning
Cutting
In
mode, when the control switch is pressed and held down the product cycles
through one complete cycle. The cycle consists of 2 phases:
1. Perform cutting operation
2. Return to initial position
After completing a cycle the product stops automatically and the control switch has to
be pressed again to start a new cycle.
You can pause a cycle at any time by releasing the control switch. Pressing the control
switch again resumes the phase in which you released the control switch.
Lock (middle position)
The movable cutting arm is locked and cannot be moved. Select this function when you
are not working with the product.
Reverse
When the control switch is pressed the movable cutting arm opens.
Use this function only if you have to release a threaded rod while a cut is in progress, for
example because the thread of the threaded rod is not correctly seated in the thread of
the cutting edges or the product's overload protection coupling has tripped.
4
Technical data
4.1
Product properties
Weight
Dimensions (L×W×H)
Ambient temperature for operation
Storage temperature
*2362838*
Meaning
The battery can remain in use.
The check to ascertain the battery's state of health
did not complete. Repeat the procedure, or consult
Hilti Service.
If a connected product can still be used, the re-
maining battery capacity is below 50 %.
If a connected product can no longer be used, the
battery has reached the end of its useful life and
has to be replaced. Consult Hilti Service.
8
STR 4-22
2.69 kg
(in accordance with EPTA-Procedure 01 without
battery)
204 mm × 103 mm × 253 mm
−17 ℃ ... 60 ℃
−20 ℃ ... 70 ℃
2362838
English
21
loading