It is the law that all gas appliances are installed by competent persons in accordance with
the current edition of the Gas Safety Installation and Use Regulations .
6mm
It is in your interest and that of safety to ensure compliance with the law.
o
o
In the UK, GASSAFE registered installers work to safe standards of practice. The hob must
also be installed in accordance with the current edition of BS 6172. Failure to install the
cooker correctly could invalidate the warranty, liability claims and lead to prosecution.
Gas Specifition
Model
CPCGM3F3121N
CPCGM3F3122W
CPGS423X
CPCGM5F5021N
CPCGM4F4121N
CPCGM4F4122W
Electrical Connection
This appliance must be earthed.
This appliance is designed to be connected to a 220-240V, 50Hz-60Hz AC electricity supply.
The wires in the mains lead are coloured in accordance with the following code;
- Green/yellow
- Blue
- Brown
The wire which is coloured green and yellow must be connected to
the terminal which is marked with the letter E or by the earth symbol.
3mm
Gas type &
pressure
Wok burner
3.3kW(240g/h)
G20 20mbar
1.28
G30 29mbar
0.93
G20 20mbar
/
G30 29mbar
/
G20 20mbar
1.28
G30 29mbar
0.93
4.0kW(291g/h)
G20 20mbar
1.50
G30 29mbar
1.00
= Earth
= Neutral
= Live
Heat input and orifice size marked(mm)
Rapid burner
3.0kW(219g/h)
1.75kW(127g/h)
/
/
1.30
0.87
1.30
0.87
3.0kW(219g/h)
1.75kW(127g/h)
/
/
17
Semi-rapid
Auxiliary-rapid
1.0kW(73g/h)
0.78
1.00
0.50
0.66
0.78
1.00
0.50
0.66
0.78
1.00
0.66
0.50
1.0kW(73g/h)
1.00
0.78
0.50
0.66