6.
Maintenance & Trouble-
shooting
6.1
Cleaning
The housing and the display of the BAT 131 may only be
cleaned using soft cloths and neutral cleaning agents.
Do not use any abrasive cleaners or coarse workshop
cleaning rags.
6.2
Service Parts / Parts Subject to Wear
Designation
Connecting cable with terminals for the
battery
<)
Printer paper
(1 roll)
<)
(Minimum order 5 rolls)
wearing part
<)
6.3
Changing the Printer Paper
i
The integrated printer only uses thermal paper in a
roll with the dimensions 57 mm x 25.9 mm.
1. Unlock the printer door gently but firmly lifting up on
the release lever.
2. Remove the empty paper roll hub.
Fig. 3:
Printer view
1 Paper Compartment
2 Paper Sensor
3 Release Lever
3. Place a new roll of paper in the compartment.
4. Pull the paper forward so that it extends past the
serrated edge of the paper slot.
Robert Bosch GmbH
Maintenance & Troubleshooting | BAT 131 | 11
Ordering number
Fig. 4:
1 684 465 625
5. Close the door and make sure the lever locks securely.
1 681 420 028
6.4
1. Identify the circled screw on the back of the tester.
2. Remove the screw.
3. Grasp the housing and firmly pull the cable assembly
from housing.
Paper feeds from underneath the roll
Changing The Cable Assembly
1 689 989 133
en
|
2013-09-09