Parkside PWH 2800 B2 Instrucciones De Utilización Y De Seguridad página 16

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 103
11.1 Damaged electrical connection cable
The insulation on electrical connection cables is often dam-
aged.
This may have the following causes:
• Pressure points, where connection cables are passed
through windows or doors.
• Kinks where the connection cable has been improperly
fastened or routed.
• Places where the connection cables have been cut due to
being driven over.
• Insulation damage due to being ripped out of the wall
outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not be used
and are life-threatening due to the insulation damage.
Check the electrical connection cables for damage regularly.
Ensure that the connection cables are disconnected from elec-
trical power when checking for damage.
Electrical connection cables must comply with the applicable
VDE and DIN provisions. Only use connection cables with the
designation H07RN-F.
The printing of the type designation on the connection cable
is mandatory.
Connection type Y
If the mains connection cable of this device is damaged, it
must be replaced by the manufacturer, their service depart-
ment or a similarly qualified person to avoid dangers.
11.2 AC motor
• The mains voltage must be 220-240 V∼.
• An extension cable with too small a conductor cross-sec-
tion causes a significant reduction in the performance of
the gardening tool. Cables up to 25 m long must have a
cross section of at least 3 x 1.5 mm
long must have a cross section of at least 2.5 mm
Connections and repair work on the electrical equipment may
only be carried out by electricians.
• The product fulfils the requirements of EN 61000-3-11
and may only be used at the following connection points:
This means that use of the product at any freely selectable
connection points is not allowed.
• Given unfavourable conditions in the power supply the
product can cause the voltage to fluctuate temporarily.
• The product is intended exclusively for use at connection
points that have a continuous current carrying capacity of
the mains of at least 100 A per phase.
• As the user, you are required to ensure, in consultation
with your electric power company if necessary, that the
connection point at which you wish to operate the product
meets the requirement named above.
For single-phase AC motors, we recommend a fuse rating of C
16A or K 16A for machines with a high starting current (from
3000 watts)!
, cables over 25 m
2
.
2
12. Cleaning and maintenance
Attention!
Pull out the mains plug before all mainte-
nance and cleaning work.
Have work which is not described in these operat-
ing instructions carried out by one of our author-
ised customer service centres. Use only original
parts.
Wear gloves when handling the cutting roller.
Before all maintenance and cleaning work, switch the device
off, pull out the mains plug and wait for the cutting roller to
come to a standstill.
12.1 Replacing the cutting roller and pressure plate
(Fig. 12 + 13)
WARNING! Risk of cuts!
Always wear work gloves before working
on the blade.
1. Switch off the device and remove the plug from the socket.
2. Turn the adjusting screw (5) approx. 2 turns anti-clock-
wise.
3. Loosen the four screws (21a) with the Allen key provided
and remove the gear cover (21) from the device.
4. Carefully pull the cutting roller (22) off the motor shaft.
5. Remove the pressure plate (23).
6. Remove dirt from the motor shaft and lightly lubricate it.
7. Place the new cutting roller (22) in the same position on
the shaft. When doing so, ensure that the cutting roller
(22) is correctly aligned (note the curvature of the blade
teeth).
8. Re-insert the pressure plate (23).
9. Insert the gearbox cover (21) and retighten the screws
(21a).
10. Adjust the pressure plate as described in point 10.9.
General cleaning and maintenance work
Do not splash the roller shredder with water.
Danger due to electric shock!
• Always keep the device, the wheels and the ventilation
openings clean. Use a brush or cloth to clean, but do not
use cleaning agents or solvents.
• Check the device, in particular the protective devices, for
damage such as loose, worn or damaged parts before
each use. Check all nuts, pins and screws for firm seating.
• Check the covers and protective devices for damage and
correct seating. Replace them if necessary.
• Keep the device dry and out of the reach of children. Do
not cover the device with nylon bags as moisture could
form.
Connections and repairs
Connections and repair work on the electrical equipment may
only be carried out by electricians.
GB/IE
11
loading