2) GENERAL INFORMATION
The THALIA P control panel comes with standard factory settings. Any change
must be made using the programmer with built-in display or universal handheld
programmer. The Control unit completely supports the EELINK protocol.
Its main features are:
-
Control of 1 or 2 24V BT motors
Note: 2 motors of the same type must be used.
-
Electronic torque control with obstacle detection
-
Limit switch control inputs based on motor selected
-
Separate inputs for safety devices
-
Built-in radio receiver rolling code with transmitter cloning.
The board has a terminal strip of the removable kind to make maintenance
or replacement easier. It comes with a series of prewired jumpers to make the
installer's job on site easier.
The jumpers concern terminals: 70-71, 70-72, 70-74, 76-77, 76-79, 81-82,
81-84. If the above-mentioned terminals are being used, remove the rel-
evant jumpers.
TESTING
The THALIA P panel controls (checks) the start relays and safety devices (pho-
tocells) before performing each opening and closing cycle.
If there is a malfunction, make sure that the connected devices are working
properly and check the wiring.
3) TECHNICAL SPECIFICATIONS
Power supply
Low voltage/mains insulation
Operating temperature range
Thermal overload protection
Dielectric rigidity
Motor output current
Motor relay switching current
Terminal
Definition
L
LINE
N
NEUTRAL
JP5
TRANSF PRIM
JP7
JP21
TRANSF SEC
10
MOT1 +
11
MOT1 -
14
MOT2 +
15
MOT2 -
20
LIgHT 24v
21
AUX 1 - 230V~
22
POWERED
CONTACT
(Max. 5A)
23
24
AUX 2 - FREE
CONTACT
(N.O.)
25
(Max. 230V 5A)
AUX 3 - FREE
26
CONTACT
(N.O.)
27
(Max. 24V 1A)
28
LOCK 12V
29
41
+ REF SWE
42
SWC 1
43
SWO 1
44
SWC 2
45
SWO 2
42
SW 1
43
SW 2
INSTALLATION MANUAL
230V~ ±10% 50Hz*
> 2MOhm 500V
-10 / +55°C
Software
mains/LV 3750V~ for 1 minute
max. 7.5A+7.5A
10A
Single-phase power supply 230V~ ±10%, 50-60Hz.
Transformer primary winding connection, 230V.
Board power supply:
24V~ Transformer secondary winding
24V= Buffer battery power supply
Connection motor 1. Time lag during closing.
Check connections shown in Fig.E
Connection motor 2. Time lag during opening.
Check connections shown in Fig.E
Flashing light 24V output max. 25W.
AUX 1 configurable output - Default setting ZONE LIgHT Output.
2ND RADIO CHANNEL/ SCA gATE OPEN LIgHT/ COURTESY LIgHT/ ZONE LIgHT/ STAIR LIgHT/ gATE OPEN ALARM/ FLASHINg LIgHT/
SOLENOID LATCH/ MAgNETIC LOCK.
Refer to "AUX output configuration" table.
AUX 2 configurable output - Default setting SCA gATE OPEN LIgHT Output.
2ND RADIO CHANNEL/ SCA gATE OPEN LIgHT/ COURTESY LIgHT command/ ZONE LIgHT command/ STAIR LIgHT/ gATE OPEN
ALARM/ FLASHINg LIgHT/ SOLENOID LATCH/ MAgNETIC LOCK.
Refer to "AUX output configuration" table.
AUX 3 configurable output - Default setting 2ND RADIO CHANNEL Output.
2ND RADIO CHANNEL/ SCA gATE OPEN LIgHT/ COURTESY LIgHT command/ ZONE LIgHT command/ STAIR LIgHT/ gATE OPEN
ALARM/ FLASHINg LIgHT/ SOLENOID LATCH/ MAgNETIC LOCK.
Refer to "AUX output configuration" table.
Type of lock logic= 0 - 12V solenoid latch output (max. 30W). Output activated with a pulse each time gate is opened.
Type of lock logic= 1 - 12V magnetic lock output (max. 15W). Output activated when gate is closed.
Limit switch common
Motor 1 closing limit switch SWC1 (N.C.).
Motor 1 opening limit switch SWO1 (N.C.).
Motor 2 closing limit switch SWC2 (N.C.).
Motor 2 opening limit switch SWO2 (N.C.).
Limit switch control motor 1.
For actuators with single-wire limit switch control.
Limit switch control motor 2.
For actuators with single-wire limit switch control.
Maximum motor power
Accessories power supply
AUX 1
AUX 2
AUX 3
LOCK
Flashing light
Dimensions
Fuses
N° of combinations
Max.n° of transmitters that can be memorized 63
(*other voltages to order)
Usable transmitter versions:
All ROLLING CODE transmitters compatible with
4) TUBE ARRANGEMENT Fi g. A
5) TERMINAL BOARD WIRING Fig. C
WARNINGS - When performing wiring and installation, refer to the standards in
force and, whatever the case, apply good practice principles.
Wires carrying different voltages must be kept physically separate from each other,
or they must be suitably insulated with at least 1mm of additional insulation.
Wires must be secured with additional fastening near the terminals, using devices
such as cable clamps.
All connecting cables must be kept far enough away from the dissipater.
Description
180W + 180W (24V
)
24V~ (demand max. 1A)
24V~safe
NO
(max.5A)
230V~ powered contact
NO contact (230V~/max.5A)
NO contact (24V~/max.1A)
Output for 12V
solenoid lock:
Solenoid latch (max. 30 W)
Magnetic (max. 15 W)
24V~ max. 25W
see Fig. B
see Fig. C
4 billion
THALIA P