Gaggenau BMP 250 710 Instrucciones De Instalación página 11

Idiomas disponibles

Idiomas disponibles

Install Appliance
Note: The appliance is heavy. It is advisable to install it
with a second person.
NOTICE
Before installing the appliance, be sure to verify the
cabinet dimensions and electrical connections.
Electrical Installation
9
WARNING
The electrical connection of the appliance must be
carried out by a qualified electrician in accordance
with local and regional safety codes.
9
AVERTISSEMENT
Le raccordement électrique de l'appareil doit être
effectué par un électricien qualifié conformément
aux codes de sécurité locaux et régionaux.
9
WARNING
This product will only operate when L1 and L2 are
powered up simultaneously. If this does not occur,
then an E300 error will be displayed. This
appliance should be installed with a branch circuit
breaker to allow L1 and L2 to be powered up
simultaneously.
9
AVERTISSEMENT
Ce produit fonctionnera seulement lorsque L1 et
L2 sont alimentés en même temps. Si ce n'est pas
le cas, le code d'erreur E300 sera affiché. Cet
appareil devrait être installé avec un disjoncteur
de branchement pour permettre à L1 et L2 d'être
alimentés simultanément.
Model
Connection
BMP 250 710
4 wire conduit
BMP 251 710
cable
Install a suitable conduit box (not included). The conduit
connector must be used to correctly attach the conduit to
the junction box.
All 4 wires must be connected, regardless if a 3 or 4 wire
connection is used.
9
WARNING
Local codes may vary; installation, electrical
connections and grounding must comply with all
applicable local codes.
9
AVERTISSEMENT
Les codes locaux peuvent varier; l'installation, les
branchements électriques et la mise à la terre
doivent se conformer à tous les codes locaux
applicables.
If local codes permit grounding through the electrical
supply neutral, connect both the white neutral wire and
the green ground wire from the oven to the neutral
electrical supply wire.
The four-wire connection is preferred, but where local
codes permit, the three wire connection is also
acceptable.
Preparing Kitchen Units
Circuit
Requirements
208 V,
20 Amps
60 Hz
or
240 V,
20 Amps
60 Hz
en-us