Regularly check the power plug and power cord for damage. If the
supply cord is damaged, it must be replaced by a special cord or
assembly available from the manufacturer or its service agent.
WARNING: This is a Class I appliance and MUST be earthed
This appliance is supplied with a 3 core mains cable coloured as follows:
Brown = L or Live
Blue = N or Neutral
Green and Yellow = E or Earth
HINTS FOR EXHAUST DUCT INSTALLATION 
The following rules must be strictly followed to obtain optimal air extraction:
• Keep exhaust duct short and straight
• Do not reduce the size or restrict exhaust duct
• When using flexible duct always install the duct pulled taut to minimize pressure loss
• Failure to observe these basic instructions will reduce the performance and increase
noise levels of the cooker hood.
• Any installation work must be carried out by a qualified electrician or competent
person.
• Do not connect the ducting system of the hood to any existing ventilation system
which is being used for any other appliance ,such as warmer tube, gas tube , hot wind
tube.
• The angle of the bend of the ventilation pipe should not be less than 120º; you must
direct the pipe horizontally, or, alternatively, the pipe should go up from the initial point
and should be led to an outer wall.
• After the installation ,make sure that the cooker hood is level to avoid grease
collection at on end.
Ensure the exhaust ducting selected for installation complies with relevant standards
and is fire retardant.
WARNING:
For safety reason, please use only the same
size of fixing or mounting screws which are
recommended in this instruction manual.
Failure to install the screws or fixing device in
accordance with these instructions may result
in electrical hazards.