Electrical Connection
1. Your oven requires 16 or 32 Ampere fuse according to the appliance's
power. If necessary, installation by a qualified electrician is recommended.
2. Your oven is adjusted in compliance with 220-240V AC/380-415V AC
50/60Hz.electric supply. If the mains are different from this specified value,
contact your authorized service.
3. Electrical connection of the oven should only be made by the sockets with
earth system installed in compliance with the regulations. If there is no
proper socket with earth system in the place where the oven will be placed,
immediately contact a qualfied electrician. Manufacturer shall never be
responsible from the damages that will arise because of the sockets
connected to the appliance with no earth system. If the ends of the electrical
connection cable are open, according to the appliance type, make a proper
switch installed in the mains by which all ends can be disconnected in case of
connecting / disconnecting from / to the mains.
4. If your electric supply cable gets defective, it should definitely be
replaced by the authorized service or qualfied electricians in order to avoid
from the dangers.
5. Electrical cable should not touch the hot parts of the appliance.
6. Please operate your oven in dry atmosphere.
Electrical connection scheme
220-240V~50/60Hz
H05 VV-F 3G 4mm²
22
380-415V 3N~50/60Hz
380-415V 3N~50/60Hz
H05 VV-F 5G 1.5mm²
H05 VV-F 4G 1.5mm²