Example 2:
Start the timer, with OFF time is sooner than ON time
ON Setting:
5 hours
OFF Setting:
2 hours
Hr
AFTER
OFF
˚C
˚C
SIMPLE
Hr
ON
AFTER
SIMPLE
˚C
˚C
SIMPLE
3.6.3.
Using the Auto Off Timer
I This timer begins countdown when the air conditioner starts, and shuts the air
conditioner off when the set time has elapsed.
I Available settings run from 30 minutes to 4 hours, in 30-minute intervals.
Notes:
*1. Weekly Timer/Simple Timer/Auto Off Timer cannot be used at the same
time.
*2. The Auto Off timer will not operate when any of the following conditions
is in effect.
The timer is off; the system is in malfunction state; a test run is in progress;
the remote controller is undergoing self-check or remote controller check;
the user is in the process of selecting a function; the user is in the proc-
ess of setting the timer; the system is under central control. (Under these
conditions, On/Off operation is prohibited.)
TEMP.
MENU
BACK
MONITOR/SET
PAR-21MAA
CLOCK
2
A 9
s How to Set the Auto Off Timer
2
AFTER
1. Be sure that you are at a standard control screen, and that the Auto Off
timer indicator is visible in the display (at 1).
When something other than the Auto Off Timer is displayed, set it to AUTO
OFF TIMER using the function selection of remote controller (see Installa-
tion Manual).
2. Hold down the Timer Menu button B for 3 seconds, so that the "Set Up"
appears on the screen (at 2).
(Note that each press of the button toggles the display between "Set Up"
and "Monitor".)
3. Press the appropriate Set Time button A as necessary to set the OFF time
(at 3).
button 4 to lock in the setting.
4. Press the Filter
Note:
Your entry will be cancelled if you press the Mode (Return) button 2 2 2 2 2 before
pressing the Filter
button 4 4 4 4 4 .
5. Press the Mode (Return) button 2 to complete the setting procedure and
return to the standard control screen.
6. If the air conditioner is already running, the timer starts countdown immedi-
ately. Be sure to check that the timer setting appears correctly on the
display.
Display shows the tim-
At Timer Start
er's
OFF
(hours remaining to
OFF).
Display changes to
show the timer's ON
At 2 hours after
setting (hours remain-
timer start
ing to ON). The time
displayed is ON set-
ting (5 hours) – OFF
setting (2 hours) = 3
hours.
The air conditioner
At 5 hours after
comes on, and will
timer start
continue to run until
someone turns it off.
AFTER
OFF
AUTO OFF
ON/OFF
B
ON/OFF
FILTER
4
DAY
CHECK
TEST
OPERATION
CLEAR
3
Timer Setting
OFF
1
AUTO OFF
s Checking the Current Auto Off Timer Setting
setting
1. Be sure that the "Auto Off" is visible on the screen (at 1).
2. Hold down the Timer Menu button B for 3 seconds, so that "Monitor" is
indicated on the screen (at 4).
• The timer remaining to shutdown appears at 5.
3. To close the monitor and return to the standard control screen, press the
Mode (Return) button 2.
s To Turn Off the Auto Off Timer...
G Hold down the Timer On/Off button 9 for 3 seconds, so that "Timer Off" ap-
pears (at 6) and the timer value (at 7) disappears.
6
G Alternatively, turn off the air conditioner itself. The timer value (at 7) will disap-
pear from the screen.
s To Turn On the Auto Off Timer...
G Hold down the Timer On/Off button 9 for 3 seconds. The "Timer Off " indica-
tion disappears (at 6), and the timer setting comes on the display (at 7).
G Alternatively, turn on the air conditioner. The timer value will appear at 7.
6
3.7. Locking the remote controller buttons
(Operation function limit controller)
I If you wish, you can lock the remote controller buttons. You can use the Func-
tion Selection of remote controller to select which type of lock to use. (For
information about selecting the lock type, see Installation Manual).
Specifically, you can use either of the following two lock types.
1 Lock All Buttons:
Locks all of the buttons on the remote controller.
2 Lock All Except ON/OFF:
Locks all buttons other than the ON/OFF button.
Note:
The "Locked" indicator appears on the screen to indicate that buttons are
currently locked.
BACK
PAR-21MAA
4
5
Timer Setting
TIMER
AFTER
OFF
1
AUTO OFF
7
˚C
˚C
AUTO OFF
7
AUTO OFF
7
AFTER
OFF
˚C
˚C
AUTO OFF
1
TIME SUN
FUNCTION
˚C
˚C
TEMP.
ON/OFF
1
MENU
ON/OFF
FILTER
4
MONITOR/SET
DAY
CHECK
TEST
CLOCK
OPERATION
CLEAR
Lock Indicator
9
loading

Este manual también es adecuado para:

Prh-p250Prh-p400Prh-p500mya