GB
MODIFYING THE PAUSE TIME
The pause time is memorised during the time programming procedure. To modify this parameter only, proceed as follows:
1- Press and hold Prog to reset, and use a screwdriver to short the jump Reset (detail 20 of fig.1).
2- Keep the Prog key pressed.
3-After three seconds led LD3 (and the flashing light) turns on. Programming procedure activated
4- Release the Prog key.
5-6 Press and hold P3 until led LD3 turns off.
7- Release P3, the led LD3 flashes and the pause time registration phase is started.
8- Wait for the required time interval
9- Press P3 to block and memorise the pause time.
Led LD3 turns off and the control unit exits programming mode.
Reset
P3
P3
LD3
MODIFYING THE PEDESTRIAN OPENING (motor mode 1)
46
P3
P3
LD3
PAUSE
Time
P3
LD3
P3
LD3
LD3
LD3
P3
P3
LD3
LD3