WIKA PSA-31 Manual De Instrucciones página 25

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

6. Commissioning, operation
Service data (SPDU service protocol data unit)
Service data is always acyclic and exchanged on the request of the IO-Link Master
With the help of the service data, the following parameter values or instrument status can be read:
IO-Link specific:
Index
Object name
(decimal)
16
Vendor name
17
Vendor text
19
Product ID
21
Serial number
24
TAG
33
Last event
40
Process data In
243
Order no
Manufacturer-specific:
Index
Object
(decimal)
name
65
SP1 or FH1
66
RP1 or FL1
WIKA operating instructions pressure switch model PSA-31 for sanitary applications
Format
Access
Visible string
R
Visible string
R
Visible string
R
Visible string
R
max. 16 Byte
R/W
Visible string
Visible string
R
16 Bit unsigned
R
Visible string
R
Format
Access
16 Bit
R/W
unsigned
16 Bit
R/W
unsigned
Factory setting
WIKA Alexander
Wiegand SE & Co. KG
www.wika.com
e.g. 1,013,093
S#
-
-
-
P#
Value range
Factory
setting
1,040 ... 9,000
9,000
1,000 ... 8,960
8,200
Remarks
This SPDU determines the
relationship with the correspond-
ing IODD.
Corresponds to serial number on
the product label (S#).
Customer-specific measuring
point number
Display of the process data that
are cyclically transferred.
Corresponds to product number
on the product label (P#)
Remarks
Switch point/window High
switching output 1
Reset point/window Low
switching output 1
EN
25
Tabla de contenido
loading

Tabla de contenido