CORBERO CCIM3FBS310 Manual De Instrucciones página 18

Idiomas disponibles

Idiomas disponibles

High temperature of ceramic plate
E3
sensor.
Temperature sensor of the IGBT failure
E4
--open circuit.
Temperature sensor of the IGBT failure
E5
--short circuit
E6
High temperature of IGBT.
Supply voltage is below the rated
E7
voltage.
Supply voltage is above the rated
E8
voltage.
U1
Communication error.
2) Specific Failure & Solution
Failure
The LED does not
come on when unit is
plugged in.
Some buttons can't work,
or the LED display is not
normal.
The Cooking Mode
Indicator comes on, but
heating does not start.
Problem
No power supplied.
The accessorial power
board and the display
board connected
failure.
The accessorial power
board is damaged.
The display board is
damaged.
The display board is
damaged.
High temperature of
the hob.
There is something
wrong with the fan.
18
Wait for the temperature of ceramic
plate return to normal.
Touch "ON/OFF" button to restart unit.
Replace the power board.
Wait for the temperature of IGBT return
to normal.
Touch "ON/OFF" button to restart unit.
Check whether the fan runs smoothly;
if not , replace the fan.
Please inspect whether power supply
normal.
Power on after the power supply is
normal.
Reinsert the connection between the
display board and the power board.
Replace the power board or the display
board.
Solution A
Check to see if plug is
secured tightly in outlet
and that outlet is
working.
Check the connection.
Replace the accessorial
power board.
Replace the display
board.
Replace the display
board.
Ambient temperature
may be too high. Air
Intake or Air Vent may
be blocked.
Check whether the fan
runs
smoothly;
if not , replace the fan.
Solution B
loading