Miller Syncrowave 180 SD 460 Manual Del Operador página 13

Idiomas disponibles

Idiomas disponibles

3-6. Typical TIG Connections
5/8, 1-1/8 in
Tools Needed:
4
5
3
3-7. Typical Stick Connections
2
1
8
7
9
6
1
2
Y Turn off power before mak-
ing connections.
1
Gas Valve In Fitting
Connection has 5/8-18 right-hand
threads.
2
Gas Valve Out Connection
Gas connection is made by means
of a flow-through type connector.
3
Torch
4
Work Clamp
5
Remote Foot Control
Connect remote control, torch, and
work clamp to receptacles as
shown.
Optional remote fingertip control
can be used.
6
Cylinder
Secure cylinder to running gear, or
other stationary support.
7
Cylinder Valve
Open valve slightly to blow dirt from
valve. Close valve.
8
Regulator/Flow Gauge
Install so face is vertical.
9
Flow Adjust
Set flow rate to 20 cfh (cubic feet
per hour) (9.4 L/min).
Y Turn off power before mak-
ing connections.
1
Electrode Holder
2
Work Clamp
Connect electrode holder and work
clamp as shown.
803 578-A
OM-361 Page 9
loading

Este manual también es adecuado para:

Syncrowave 180 sd 575