1. CODES
DM590
DM591
DM592S
DM592P
2. INTRODUCTION
Thank you for purchasing LOGIKO sphygmomanometer by Moretti S.P.A. product range. This user's
manual provides some suggestions as how to correctly use the product you have chosen and gives
some valuable advice for your safety. Please read through the manual carefully before using the product.
Should you have any queries, please contact your retailer for advice and assistance.
In case of doubts, we recommend to contact the dealer who can help and advice you properly.
WARNING!
• Do not use the product for a purpose not indicated in this manual
• Moretti S.P.A declines all responsibilities for any consequences resulting from an incorrect
use of this product and from unauthorized alteration to the frame of the product.
• The manufacturer reserves the right to change the information contained in this document
without previous notice.
• This device is intended for non-invasive measuring of an adult individual's systolic, diastolic
blood pressure and heart rate using the oscillometric method.
• The device is not intended to use on infants and children.
• The device is designed for home or clinical use.
• All values can be read out in one LCD Display.
• Measurement position is on adult wrist only.
3. INTENDED USE
The digital sphygmomanometer wrist type is measurement device for systolic and diastolic blood
pressure.
4. REGULATIONS AND DIRECTIVE OF REFERENCE
Safety standard:
EN 60601-1
Medical electrical equipment part 1: General requirements for safety
EMC standard:
EN 60601-1-2
Medical Electrical Equipment -- Part 1-2: General Requirements For Basic Safety And Essential
Performance -- Collateral Standard: Electromagnetic Disturbances – Requirements And Tests
Performance standards:
IEC 80601-2-30
Medical electrical equipment – Part 2-30: Particular requirements for the basic safety and essential
performance of automated non-invasive sphygmomanometers.
EN 1060-3
Non-invasive sphygmomanometers - Supplementary requirements for electromechanical blood
pressure measuring systems.
ISO 81060-2
Non-invasive sphygmomanometers - part 2: clinical validation of automated measurement type.
5. GENERAL WARNINGS
1.
Do not confuse self-monitoring with self-diagnosis. Blood pressure measurements should only be
interpreted by a health professional who is familiar with your medical history.
Digital sphygmomanometer desk type, display 3"
Digital sphygmomanometer desk type, display 4"
Digital sphygmomanometer desk type, display 4.8"
Digital sphygmomanometer desk type, display 4.8" talking
3
ENGLISH