poolstar SPAWER POOLEX O'SPA Manual De Instalación página 125

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
WARNING: Under normal conditions, a suitable heat pump can heat up the tub water
by 1°C to 2°C per hour. It is therefore normal that you do not feel any difference in
temperature at the outlet level when the heat pump is on.
A heated tub must be covered and insulated to avoir any heat loss.
6.1
Breakdown and faults
In the event of a problem, the heat pump's screen displays an error code instead of temperature
indications. Please consult the table below to find the possible causes of a fault and the actions to
be taken.
Code
Ambient temp too high or too low
E00
Température de l'air trop chaude ou trop froide
Inlet water temp sensor failure
E01
Défaut du capteur de température d'entrée
Ambient temp sensor failure
E02
Défaut du capteur de température ambiante
Too high discharge gas temp
E03
Température de gaz trop élevée
Discharge temp sensor failure
E04
Défaut du capteur de température de refoulement
Coil temp sensor failure
E05
Défaut du capteur de température de la bobine
Low pressure protection
EL
Protection basse pression
High pressure protection
EH
Protection haute pression
Water flow protection
E06
Protection contre le débit d'eau
6. Repairs
Fault Name
Action
Shutdown protection
Shutdown protection
Shutdown protection
Shutdown protection
Shutdown protection
Shutdown protection
Shutdown protection
Shutdown protection
Shutdown protection
EN
| 27
loading