1. General information
1.1
General terms and conditions of delivery
All products and packaging, even those delivered carriage paid, travel at the risk of the recipient.
Persons responsible for accepting delivery of the device must perform a visual inspection to make
a note of any damage that may have occurred during transportation (refrigeration circuit, casing,
electric box, frame). Any damage occurring during transportation must be noted by the recipient
on the delivery receipt of the carrier, and confirmed by registered post sent to the carrier within 48
hours.
The device must be stored and transported upright at all times, on a pallet, and in its original
packaging. If the device has been transported in a horizontal position, please wait at least 24
hours prior to connecting it.
1.2
Safety instructions
WARNING: Please read carefully all safety instructions before using the device. As
the instructions noted in this document are essential to your safety, please respect
them carefully.
Installation and maintenance
Only a qualified person may undertake installation, start-up, servicing and repairs, in compliance
with current standards.
Before operating or undertaking any work on the devoce (installation, start-up, use, servicing), the
person responsible must be aware of all the instructions in the heat pump's installation manual as
well as the technical specifications.
Under no circumstances install the equipment close to a source of heat, combustible materials or
a building's air intake.
If installation is not in a location with restricted access, a heat pump protective grille must be fitted.
To avoid severe burns, do not walk on pipework during installation, repairs or maintenance.
To avoid severe burns, prior to any work on the refrigerant system, turn off the heat pump and wait
several minutes before placing temperature and pressure sensors.
Check the refrigerant level when servicing the heat pump.
Check that the high and low pressure switches are correctly connected to the refrigerant system
and that they turn off the electrical circuit if tripped during the equipment's annual leakage
inspection.
Check that there is no trace of corrosion or oil stains around the refrigerant components.